Assembly Instructions

Ensure that the laser light cables are installed without tensile
stress, buckles and torsion-free.
The bend radius of the laser light cable must not be smaller
than 200 mm.
Connecting the laser light cable to the
focusing optics
The following instructions describe how to proceed step-by-step
when connecting an LLK to a focusing optics.
In the following instructions, we assume that the optics cannot
be rotated on the carrier. If the optics can be rotated, you can
vary the described procedure as mentioned above:
Mount the focusing optics.
Rotate the focusing optics into a horizontal position.
Connect the LLk as described below.
Conditions
This concludes the complete assembly of the focusing optics.
You have removed the transport packaging of the focusing
optics and put it on a clean surface.
The plug receptacle of the focusing optics is closed with a
sealing plug.
The LLK plug you want to connect to the focusing optics is
flexible so that it can be plugged in the plug receptacle with-
out applying tensile force to the LLK.
A protective cap is attached to the LLK plug.
The carrier on which you want to mount the focusing optics
is mechanically and electrically, if required, prepared for
mounting.
Means, Tools, Materials
Adhesive PVC tape, 19 mm, material no.: 1420313
LLK-D protective collar, material number 1416727
2
22
Installation
2020-01 22-50-17-CRen
Installing the laser light
cables
bend radius