Assembly Instructions

1 0 V
2 +Vs
3 Output signal
Proximity switch plug terminal assignment Fig. 2-30
Operating voltage range +Vs: 10 - 30 V DC
Max. current consumption (without load): 12 mA
Operating voltage: 24 V DC.
Protective glass cassette available: 24 V
Protective glass cassette not available: 0 V
3.8 Lighting connection
The processing point lighting is supplied with 24 V.
Connection for lighting, M8 connector
Fig. 2-31
Pin Supply line Designation Note
1 Brown +24 V Max. supply voltage 30 mA
3 Blue GND Central earth
4 Black TRIGGER On: 8 - 24 V
Off: open or < 0.5 V
X1 connection for lighting, M8 connector, 3-pole Tab. 2-6
Note
The lighting can also be controlled via the image processing soft-
ware VisionLine; see the operator's manual "VisionLine", doc.
no.: 22-50-12-A0-CR.
22-50-17-CRen
2020-01
Installation
235
Proximity switch connection
data
Signal level at output A