Assembly Instructions

1. Integration into a system environment
The focusing optics is composed by modules according to the
requirements of your application. This means that each focusing
optics has different specifications:
for the dimensions of the focusing optics
for the fastening of the focusing optics.
for the spaces which have to be kept free around the focus-
ing optics.
Dimensional details about the focusing optics and the clearan-
ces that have to be maintained are described in the following
documents:
in the dimensional drawing of the focusing optics
in the installation instructions for focusing optics D50,
doc. no.: 22-50-17-A1-DH.
These documents have been delivered together with your laser
device or with the separately delivered focusing optics.
The dimensional drawing contains:
all dimensions in millimeters [mm]
Clearances to be maintained in millimeters (mm).
Letters as a reference to the installation guideline.
How to deal with dimensional drawings and installations instruc-
tions is described by means of an example in the following sec-
tions:
1.1 Fastening
Fastening of the focusing optics is determined by the modules
built in.
There are the following fastening methods for the focusing
optics:
on the empty cube.
At the cube with its different versions:
cube.
90° cube.
At the 2 x 90° double deflection.
The fastening screws (4 x M4) have to be tightened to a torque
of 2.5 Nm.
2
4
Integration into a system environment
2020-01 22-50-17-CRen
Documents
Dimensional drawing and
installation guideline