Connecting pieces are used to fasten focusing optics to a sup-
port.
Note
In the case of focusing optics BEO D50 Smart, the fastening
must be insulated.
The cube has a separating plate, the 90° cube has a deflec-
tion mirror. The 2 x 90° double deflection has two deflection mir-
rors.
The laser light or the visible light for observation is deflected in
the cubes.
The empty cube extension however contains no optical element.
If the deflector mirror or separating plate are damaged,
your eyes and your skin may be exposed to laser light!
Laser light may be emitted straight ahead at a high power,
thereby burning your skin or causing permanent damage to
your eyes.
Ø
Always close any unused connection for observation or a
sensor system with a plate.
Ø
Wear laser protection glasses that are appropriate for the
wavelength of the laser light.
2.7 BEO D50 Smart interface module
1 Cooling water monitoring mod-
ule
2 Interface module
BEO D50 Smart interface module Fig. 3-14
The BEO D50 Smart interface module with cooling water moni-
toring module is attached to the collimator of the focusing optics
and connects the focusing optics with the electronics of the
laser device. It also monitors the scattered light on the LLK pro-
tective glass.