1 Tip 1 (69 128 mm)
2 Locking screw (3 x)
3 Sleeve
4 Tip 2 (178 235 mm)
Fig. 4-8
1. Loosen the clamping screws (2).
2. If necessary, shorten the tip 2 (4) to the desired length.
3. Insert the appropriate tip 1 or 2 (1 or 4) into the sleeve (3).
4. Position the caliper between the focusing optics and work-
piece at an easily accessible point where the working dis-
tance can be adjusted or checked.
5. Screw in the clamping screws by hand and tighten them
carefully with a screwdriver.
2.5 Adjusting the line laser
Condition
The working distance has been set correctly (e.g. by welding
a focus series on anodized aluminum sheet).
Means, Tools, Materials
Allen key
4
14
Adjusting the focal position
2020-01 22-50-17-CRen
Caliper L69-235