User Guide
Table Of Contents
1
3
4
2
C
T
-
0
0
4
8
6
1 camera
2 Safety screw
3 Adjustment screw (2x)
4 Allen screws (2x)
Fastening the camera Fig. 4-17
2. Undo the two Allen screws (4) and remove the cover plate.
3. Turn the setting ring below by hand or with a hexagonal
socket screwdriver ≤ AF2.
4. watch the monitor with the camera picture
5. If the image of the processing point is sharp, reinstall the
cover and tighten the screws.
4.2 Adjusting the cross hairs
The cross hairs of the focusing optics have been adjusted to the
center ex works. Readjust the cross hairs when maladjusted.
Condition
■
The connected laser device has been switched off and
secured against renewed switching on, e.g. by means of a
shackle padlock.
or
■
The light path to the focusing optics is blocked.
Means, Tools, Materials
■
Allen key, 90°, 2.0 mm
■
Allen key, 90°, 2.5 mm
22-50-17-CRen
2020-01
Adjusting the Gen 2 observation optics
4‐25
Adjusting the picture
sharpness