TS10 TS10 ring e d l o 0S 0 Iron Instruction Manual Version 1.0.1 Please read this manual before operating the TS100(this instruction manual is based on APPV2.
Content 1 ! WARNING:Failure to comply a WARNING may result in serious injury to the user or others. ! CAUTION:Failure to comply a CAUTION may cause damage to the product or other equipments. NOTE:Annotations,operation notes or additional information.
1 Safety Statememt 1.1 General Safety Use only certified power source/adaptors from your region. (please refer to 3.0 for specifications) Do not operate in humid environment. Do not operate in inflammable/explosive environment. Keep the surface of the product clean and dry. 1.
1 Safety Statememt 1.3 Warnings When using TS100, Turn the power off when not in use,or left unattended. When power is ON,tip temperatures will between 100℃~400℃(212℉~752℉),please be careful. Please don’t operate TS100 when it’s wet or operate it with wet hands,which will cause an electric shock. 1.4 Cautions When using TS100, ! • The handle is constructed with precision, dropping shall be avoided. • After continuous use up to 40 minutes, the handle surface temperature will reach 50℃~60℃.
2 Overview 2.1 Ports and Control Panel Introduction 5 4 3 2 1 6 9 7 10 8 1.The tip setscrew 2.Button A 3.Button B 4 . Ground cable fixing screw 5 . Power connector 6 . Micro USB 7 . DC5525 12-24V port 8 . Soldering tip port 9 . Soldering tip connector 10 .
2 Overview 2.2 Specifications Screen USB port Power port Dimensions OLED Micro USB DC5525 Operation unit Length:96mm,Diameter:16.5mm Heating unit Length:72+33mm,Diameter:5.5mm Weight 33g(power adaptor not included) 2.
3 Power Adaptor Selection Before connecting DC5525(12-24V)power adaptor,check if the adaptor is in good condition as below standard. We would recommend the DYS404-190210V (19V,2.1A)power supply as an accessory for TS100. Operation voltage Power Electric current Time required to increased tip temperature from 30℃ to 300℃ 12V 17W >1 . 4A 40s 16V 30W >1 . 9A 20s 19V 40W >2 . 1A 15s 24V 65W >2 .
4 Operation 4.1 TS100 Installation 1. Loosen the tip setscrew, insert the soldering tip connector and tighten the screw; 2. Connect the ground wire to the ground wire setscrew ; 3. Connect the DC connector to TS100, connect the power cord and turn on the power accordingly. Note: If the screen displays "sen-err " when it’s plugged, means the soldering iron tip is not properly fixed, please re-install it properly. 4.
4 Operation 4.3 Basic Control 4.3.1 Screen Display P re ss V er 2 .0 1 When plugged into DC12-24V power adaptor ,TS100 will display its logo, Version number and its standby screen in sequence. D FU 1 .0 When plugging into DC 12-24V power adaport ,pressing Button A at the sametime will enter DFU mode,"DFU1.0" will appear on OLED screen . To exit DFU mode: unplug and plug in the device again without pressing any button ,then it will enter standby mode.
4 Operation 4.3 Basic Control 4.3.2 Automatic Calibration P re s s Press Button B in standby mode to enter the thermometer mode 2 4℃ In thermometer mode, press 2 buttons at the same time to enter the calibration mode V Ca l_X Cal _V Display shows when calibration is succedd.
4 Operation 4.3 Basic Control 4.3.
4 Operation 4.3 Basic Control 4.3.4 Temperature Adjustment 300℃ In standby mode, press Button A will enter preset temperature 3 00℃ Temperature down: In temperature adjusting mode, hold Button A for at least 2 seconds, until display reads the temperature you want. 24 6℃ 20 0℃ Release Button A when display reads the expected temperature, and TS100 will automatically adjust to it.
4 Operation 4.3 Basic Control 4.3.
4 Operation 4.3 Basic Control 4.3.5 Sleep Mode 2 00℃ In operation mode, when leaving TS100 for more than 180 seconds( 3 minutes in Default) will trigger the sleep mode, and temperature will automactically adjust to preset sleep temperature. 3 00℃ When working, TS100 will restart to operation mode and temperature will automatically heat up to preset temperauture(300°C in Default).
4 Operation 4.
5 Soldering Iron Tip 5.1 Changing Soldering Tips 1.Unplug TS100 before changing. 2.Loosen the tip setscrew. 3.Pull out the tip, replace with another one. 4.Tighten the screw. Note: When TS100 displays "sen-err", it means the soldering iron tip is not installed properly.
5 Soldering Iron Tip 5.2 Choosing Soldering Iron Tips Note: Choosing the right tips will help you to work more efficient 45 ° 10.0 45 1 0.0 ° 15.0 11.5 TS-D24 TS-K TS-BC2 TS-B2 5.3 Soldering Iron Tip Maintenance (1) Before switching off, wipe the tip’s soldering side with some solder. (2) Do not leave the tip in high temperature for long time, which may causeit burn out. (3) Do not push too hard while soldering, which will damage the tip.
6 Tr o u b l e Problem 1:No Display Shooting Guide Check:If the cable is broken Check:Is there any data in USB mode Check:If the screen needs to be replaced Problem 2:Every time when installing a new tip, the temperature status display random numbers Problem 3:Soldering iron restart automatically Means the machine is checking status,which is normal Check 1:Is it properly plugged into the power source? Check 2:Is the voltage too low? (need to be set up in the config file) Check 1:Is the tip first t
6 Tr o u b l e Problem 6:OLED displays"High-Vt" Shooting Guide Check:Is the voltage too high?(over 24V) Check 1:Is the soldering iron installed propely? Problem 7:OLED displays "Sen-err" Check 2:If check 1 passes, then replace the soldering iron tip 1.Tip temperature is over 400℃ 2.The soldering side of the tip is not applied with solder properly 3.Lack of flux during operation Problem 8: The tip doesn’t stick to the solder 4.Rub the tip against dry or high sulfur sponge or fabric 5.
7 Te c h n i c a l S u p p o r t 7.1 Standard service 1 year of warranty will be provided for one year, if the damage was not caused by false manipulation by the user.Plesae contact your retailer for warranty detail Tips are consumables, once it’s used, no replacement will be provided. 7.2 Default Parameter Setting Connect TS100 to your PC with USB data cord, OLED will display "CONFIG" and means it's in setting mode. Open config.txt file from the USB drive, set the default parameters.
7 Te c h n i c a l S u p p o r t 7.3 Firmware Update 1.Visit www.miniware.com.cn and download the latest TS100 firmware to your PC. 2.Connect TS100 to your PC with USB data cord,meanwhile,press TS100’s Button A to enter DFU mode once a “DFU1.0” notice appears on the screen. A virtual disk with 8 serial numbers will appear on your PC. 3.Copy the hex firmware to the root directory of that disk. When the extension of the firmware changes from “hex” to “rdy”, disconnect USB and the firmware is upgraded. 7.
8 Legal Statements 8.1 Disposal Do not dispose this product with domestic waste Handling and recycle:Disposal of the product shall be manipulated according to laws and regulations in your area. 8.2 Statement of Fulfilling FCC Standard This device fulfills part 15 of the FCC regulations Device must fulfill below 2 conditions: (1) Device must not generate interference (2) Device must be able to resist any interferences on it, including interferences that could cause dangerous manipulation 8.