Product Manual
Moisture Minder® EDV Electronic Solenoid Valve P/N 21999-0177
• Condensate enters through the inlet side of
the valve.
• Debris is captured inside the internal
strainer.
• When valve activates condensate flows thru
the strainer up to the orifice and out the back
discharge port
• Debris is captured by internal strainer which
pr
events fouling of orifice
Built-in Ball Valve
Discharge or
Outlet Port
1/4”NPT
Bulk Head Mounting
3/4-16 UNF Threads
Warning: Install fitting and drain line to clean out and discharge ports and
route to a safe area to avoid injury to self or others
• No disassembly needed for cleaning internal strainer
• Opening ball valve allows system pressure to blow out debris
• Serves as manual drain
Clean Out Port
1/4”NPT
Open only to clean
strainer or to
manually drain the
tank
Internal Strainer
For Compressors (Up To 300HP)
Dryers, Aftercoolers, Separators,
and Filters
Inlet Port
¼” NPT I.D.
½” NPT O.D.
U.S. Patent # 6571830 EPO # 01306857.2
764-2006 03
Recommend on time - ½ to 2 seconds
(It is more efficient to cycle your valve more often with less on time)
Off time, or cycle time, setting may need to be
adjusted depending on condensate output