Moisture Minder® EDV Electronic Solenoid Valve P/N 21999-0177
Condensate enters through the inlet side of
the valve.
Debris is captured inside the internal
strainer.
When valve activates condensate flows thru
the strainer up to the orifice and out the back
discharge port
Debris is captured by internal strainer which
pr
events fouling of orifice
Built-in Ball Valve
Discharge or
Outlet Port
1/4”NPT
Bulk Head Mounting
3/4-16 UNF Threads
Warning: Install fitting and drain line to clean out and discharge ports and
route to a safe area to avoid injury to self or others
No disassembly needed for cleaning internal strainer
Opening ball valve allows system pressure to blow out debris
Serves as manual drain
Clean Out Port
1/4”NPT
Open only to clean
strainer or to
manually drain the
tank
Internal Strainer
For Compressors (Up To 300HP)
Dryers, Aftercoolers, Separators,
and Filters
Inlet Port
¼” NPT I.D.
½” NPT O.D.
U.S. Patent # 6571830 EPO # 01306857.2
764-2006 03
Recommend on time - ½ to 2 seconds
(It is more efficient to cycle your valve more often with less on time)
Off time, or cycle time, setting may need to be
adjusted depending on condensate output