Product Manual

Date Printed: 6/19/2018
764-2056
INSTALLATION INSTRUCTIONS
WARNING
Your safety is important. System pressure must be released prior to any
installation or service. Failure to follow instructions could result in
operating failure or product damage. Always install filtration with the
arrows indicating the direction of airflow. Use only appropriate thread
sealant on all connection fittings unless otherwise specified. Do not alter
the filtration from its original design as this may cause failure in its
operation parameters.
FILTER SPECIFICATIONS
DESCRIPTION
Tsunami filters are machined from the highest quality materials &
anodized inside & out to ensure ultimate durability against trapped
contaminates. Our cutting-edge technology is rigorously tested to
outperform your expectations regardless of the industry or application.
Water Separators remove water and up to 1 quart per minute & filters
particulate down to 10 micron.
Oil Coalescing Filters remove oil aerosols down to .001 ppm & traps
particulates down to .01 micron.
Activated Carbon Filters remove oil vapor down to .003 ppm,
removing odor & taste from the air.
Installation Instructions:
Tsunami Filtration
20
Series
50
Series
120
Series
240
Series
800
Series
Maximum Pressure
250 psi 200 psi
Maximum Flow (scfm)
20 50 120 240 800
Maximum Temp (°F)
175
Port Size (npt)
1/4” 1/2” 1” 2” 3”
Note: Tsunami regulators have a maximum temperature of 122 °F
1. If using a Tsunami filter Mounting Bracket, secure bracket to wall
prior to plumbing filter into air system.
2. Using supplied hardware, attach Tsunami filter to mounting bracket.
3. Using arrow on filter head, plumb unit into system piping in the
desired direction of airflow. Use appropriate thread sealant.
FILTER INSTALLATION - OPTION 1 - MOUNTING BRACKET
Inlet
Outlet
FILTER INSTALLATION - OPTION 2 - MOUNTING PANEL
Inlet
Outlet
Z
1. If installing filter directly inline with air system plumbing, verify that
there is adequate support to hold weight of filter. For filter models
including electronic drains, verify there is adequate space between
the wall and filter to allow for removal of tube during maintenance.
2. Using arrow on filter head, plumb unit into system piping in the
desired direction of airflow. Use appropriate thread sealant.
FILTER INSTALLATION - OPTION 3 - MOUNTING INLINE
1. If using a Tsunami filter package Mounting Panel, secure panel to
wall prior to plumbing filter package into air system.
2. Using arrows on filter heads, plumb unit into system piping in the
desired direction of airflow. Use appropriate thread sealant.
INSTALLATION & SERVICE REQUIREMENTS
IMPORTANT: The follow maintenance schedule is recommended for all
Tsunami Filters and Filtration Packages. Failure to follow instructions
could result in operating failure or product damage.
Oil Coalescing Filter - Mandatory Every 6 Months
Activated Carbon - Mandatory Every 6 Months
Water Separator - Zero Maintenance Required. Clean as needed.
Tsunami filters come standard with automatic float drains. If ordered
with pneumatic or electronic drains, follow the respected installation
procedures listed here:
Pneumatic: Run pilot line from bottom nipple of filter drain
to desired pilot signal. Drain line runs out of side port.
Electronic: Plug 110v cord into wall.