INSTALLATION INSTRUCTIONS FOR MOISTURE MINDER
®
AUTOMATIC DRAIN
USING OPTIONAL INSTALLATION KITS (P/N 21999-0316 / 21999-0317)
READ ALL INSTRUCTIONS CAREFULLY BEFORE INSTALLATION RETAIN FOR FUTURE USE
WARNING
BEFORE SERVICING OR WORKING ON ANY COMPRESSED AIR SYSTEM COMPONENTS,
USE THE MANUFACTURE’S MANDATORY SAFETY SHUT DOWN PROCEDURE
FOR ALL COMPONENTS.
1. THIS INCLUDES DISCONNECTING ELECTRICAL POWER AND USING REQUIRED SAFETY LOCKOUT TAGS.
2. AIR PRESSURE IN SYSTEM MUST BE BLED DOWN TO ZERO
3. SAFETY GLASSES MUST BE WORN.
4. A LICENSED ELECTRICIAN MUST DO ALL ELECTRICAL WORK
5. ALL STATE AND LOCAL CODES MUST BE FOLLOWED.
6. TEFLON PIPE SEALANT SHOULD BE USED ON ALL PIPE FITTINGS.
Mounting the drain valve with Deluxe Installation Kit
• Depressurize system before installation
• Install bracket at desired location for drain mounting
• Attach drain using supplied nut and lock washer then
install fittings as shown in photo to the right
• Tee unloading line and route to signal air end of drain
(Note: use tube inserts when using nylon tubing)
• Install strainer, with nipple and elbow provided, to bottom of tank**
• Route condensate from tank strainer to drain with ¼” tubing
• Use 1” barbed fitting and 2” clear tubing to route drain discharge
**