Use and Care Manual
CIRCUIT BREAKER
GFCI
SW.
ON
LY
OFF
TEST
TEST
RESET
RESET
(6) Press the GFCI RESET button.
The GFCI green LED lamp lights up.
(7)
Turn the circuit breaker ON position
With the RESET button in and engine running, turn the circuit breaker to the ON position. The circuit
breaker should remain in the ON position.
The circuit breaker will not remain in the ON position if the RESET button is extended.
If the GFCI and circuit breaker do not function as described, take the generator to an authorized TSURUMI
generator dealer for repair.
During generator use, if the GFCI RESET button extends and the circuit breaker trips, this usually indicates
a faulty power tool, appliance, or cord.
If that occurs, perform test steps 1 through 6 to verify that the GFCI and circuit breaker are in proper
working order. If the GFCI and circuit breaker test correctly, then you will know that the fault is in the power
tool, appliance, or cord. Repair or replace the faulty power tool, appliance, or cord before further use.
6. Press the RESET button.
6. The GFCI green LED lamp
lights up.
7. Turn the ON position.