Use and Care Manual

Tsurumi’s Operation, Service and Repair Manual
Troubleshooting
36
5-4 Electrical Limits Reference Chart
(1) The Electrical Limits Reference Chart, Table 5-1, provides a ready reference to electrical
component limits.
Table 5-1: Electrical Limits Reference Chart
Model Rotor Stator Condenser
Field
Coil
Insulation
(1)(2)
AC Winding
Red/White
AC Winding
Red/White
Condenser
Winding
Yellow/Yellow
Insulation
(2)(3)
Capacitance
TPG4-3000HDX
1.70
> 1 M
0.58 0.58 1.56
> 1 M 14µF
TPG4-4500HDX
1.75
> 1 M
0.29 0.29 0.74
> 1 M 36µF
TPG4-6000HDX
1.58
> 1 M
0.22 0.22 0.57
> 1 M 36µF
TPG4-7000HDX
1.14
> 1 M
0.21 0.21 0.57
> 1 M 36µF
TPG4-7000HDXE
1.76
> 1 M
0.18 0.18 0.46
> 1 M 36µF
(1) Measure insulation across one of the solder terminals and the core of the rotor.
(2) Measure between stator leads as follows: BLUE lead and core; WHITE lead and core;
YELLOW lead and core: and BROWN lead and core.
WARNING: DO NOT USE ANY PART WITH INSULATION RESISTANCE OF LESS THAN 1 M
.
LOW INSULATION RESISTANCE IS AN INDICATION THAT THE PART IS FAULTY
INSULATION AND MAY CAUSE ELECTRICAL LEAKAGE AND POTENTIALLY
FATAL ELECTRICAL SHOCK. REPLACE ALL FAULTY PARTS.
5-5 Troubleshooting Charts
(1) This section provides the instructions for generator checkout and fault isolation. The
troubleshooting procedures are presented in Table 5-2. The table lists typical faults, presents
probable cause, and provides the remedy for the majority of generator operational faults.