Removal/Installation
66
Fi1gure 6-9: Bearing Puller in Use
Figure 6-10: Removal of Through Bolt
NOTE: In the steps that follow, motor oil is used to generate hydraulic pressure. Hydraulic pressure is
used to separate the tight-fitting engine and generator shafts.
13. Refer to Figure 6-10. With the generator in the vertical position, pour a small amount of motor
oil in the bore in the center of the rotor shaft. (The oil level should be flush with the end of the
rotor shaft.)
Puller
Threaded Rod
Bearing
TPG3 FIG 6-9
Through
Bolt
TPG3 FIG 6-10
TPG4 FIG 6-9
TPG4 FIG 6-10