User's Manual

Table Of Contents
B. MIBS
120 DESCRIPTION
121 "Smallest correction value ever applied by the clock
122 synchronization algorithm ."
123 ::= { tteSwitchingEngineVnV 10 }
124
125 tteSweClockCorrLargest OBJECT -TYPE
126 SYNTAX INTEGER
127 ACCESS read -only
128 STATUS mandatory
129 DESCRIPTION
130 "Largest correction value ever applied by the clock
131 synchronization algorithm ."
132 ::= { tteSwitchingEngineVnV 11 }
133
134 tteSweNumberOfSyncLoss OBJECT -TYPE
135 SYNTAX INTEGER (0..65535)
136 ACCESS read -only
137 STATUS mandatory
138 DESCRIPTION
139 "Number of transitions of the clock synchronization state
140 machine from SYNC state or STABLE state to anything else than
141 SYNC state or STABLE ."
142 ::= { tteSwitchingEngineVnV 12 }
143
144 tteSweMembershipVectorCurrent OBJECT -TYPE
145 SYNTAX INTEGER (0..255)
146 ACCESS read -only
147 STATUS mandatory
148 DESCRIPTION
149 "Membership value of the in - schedule integration protocol
150 control frame received within the most recent acceptance
151 window that has the largest weight.
152 NOTE: The field contains valid data only if the IP is
153 synchronized ."
154 ::= { tteSwitchingEngineVnV 13 }
155
156 tteSweMembershipVectorSmallest OBJECT -TYPE
157 SYNTAX INTEGER (0..255)
158 ACCESS read -only
159 STATUS mandatory
160 DESCRIPTION
161 "Membership vector with the smallest number of flags set of
all
162 in -schedule integration frames ever processed by the
163 synchronization state machine . The field will maintain its
164 value also when synchronization is lost."
165 ::= { tteSwitchingEngineVnV 14 }
166
167 tteSweMembershipVectorLargest OBJECT -TYPE
168 SYNTAX INTEGER (0..255)
169 ACCESS read -only
170 STATUS mandatory
171 DESCRIPTION
172 "Membership vector with the largest number of flags set of all
173 in -schedule integration frames ever processed by the
174 synchronization state machine . The field will maintain its
© TTTech Computertechnik AG 2019. All rights reserved.
Confidential and Proprietary Information
42
Document Number:
D-863-M-05-001