B. MIBS
286 ::= { tteSweEthPortStatusTableEntry 7 }
287
288 tteSweEthPortNoLossUnknownVl OBJECT -TYPE
289 SYNTAX Counter
290 ACCESS read -only
291 STATUS mandatory
292 DESCRIPTION
293 "Number of frames which were dropped because the Virtual
Link
294 ID has not been configured for this port ."
295 ::= { tteSweEthPortStatusTableEntry 8 }
296
297 tteSweEthPortNoLossCrcError OBJECT -TYPE
298 SYNTAX Counter
299 ACCESS read -only
300 STATUS mandatory
301 DESCRIPTION
302 "Number of frames received on the port carrying a wrong CRC
303 checksum ."
304 ::= { tteSweEthPortStatusTableEntry 9 }
305
306 tteSweEthPortNoLossLengthError OBJECT -TYPE
307 SYNTAX Counter
308 ACCESS read -only
309 STATUS mandatory
310 DESCRIPTION
311 "Number of frames that are longer than 2047 bytes ."
312 ::= { tteSweEthPortStatusTableEntry 10 }
313
314 tteSweEthPortNoLossSofError OBJECT -TYPE
315 SYNTAX INTEGER (0..255)
316 ACCESS read -only
317 STATUS mandatory
318 DESCRIPTION
319 "Number of frames that start with a byte other than 0x55 or
320 0xD5 , have a byte other than 0xD5 being the first byte that
321 is different than 0x55 or 0xD5 , or that terminated before
322 the SOF delimiter byte."
323 ::= { tteSweEthPortStatusTableEntry 11 }
324
325 tteSweEthPortNoLossAlignmentError OBJECT -TYPE
326 SYNTAX INTEGER (0..255)
327 ACCESS read -only
328 STATUS mandatory
329 DESCRIPTION
330 "Number of frames having a length that is not a multiple of
331 eight bits (at the given line speed )."
332 ::= { tteSweEthPortStatusTableEntry 12 }
333
334 tteSweEthPortNoLossMiiError OBJECT -TYPE
335 SYNTAX INTEGER (0..255)
336 ACCESS read -only
337 STATUS mandatory
338 DESCRIPTION
339 "Number of frames that terminated with the MII error input
340 being asserted ."
© TTTech Computertechnik AG 2019. All rights reserved.