ADJUSTMENT OF THE VU METER READING "COMPRESSION":
1) Turn the
THRESHOLD
-control fully cou nter-clockwise.
2) Switch the
METER
-selector to Compression.
3) Set the
RATIO-
control a t 1,5:1
4) Apply a signal of 1 kHz, 0,0 dBU into the input of the compressor.
5) Adjust the
GAIN-
control to an output-reading of 0,0 dBU.
6) Adjust P8until the meter is reading 0VU.
7) Apply a DC-voltage of +250,0 mV into the sidechain jack socket and observe that the
output level has dropped to -10,0 dBU. If this is not the case, adjust the compressio n
tracking (see above )
8 Adjust P7(-10VU) until the meter i s reading -10,0 VU.
9) Remove the DC-voltage fr om the sidecha in jack socket.
10) Repeat step 6 - 9.
NB: The VU-meter accuracy should be within +/- 1dBwhen readi ng compression.