Manual

LYDKRAFT ApS
Mose Allé 20, DK 2610 Rødovre
Denmark
6
ADJUSTMENT OF THE LED DISPLAY READING "VU":
1) Switch the METER-selector to Output.
2) Apply a signal of 1 kHz, 0,0 dBU into the input of the compressor.
3) Adjust the GAIN-control to an output-reading of +4,0 dBU.
4) Adjust P10 to a LED display reading of 0 VU.
The -1 LED shall just turn off and the 0 LED shall just turn on.
ADJUSTMENT OF THE LED DISPLAY READING "COMPRESSION":
1) Turn the THRESHOLD-control fully counter-clockwise.
2) Switch the METER-selector to Comp.
3) Set the RATIO-control at 2:1
4) Apply a signal of 1 kHz, 0,0 dBU into the input of the compressor.
5) Adjust the GAIN-control to an output-reading of 0,0 dBU.
6) Adjust P 9 until the LED display is reading 0 VU.
The -1 LED shall just turn off and the 0 LED shall just turn on.
7) Apply a DC-voltage of +250,0 mV into the side chain jack socket and observe that the
output level has dropped to -10,0 dBU. If this is not the case, adjust the compression
tracking (see above)
8) Adjust P 8 until the LED display is reading -10,0 VU.
The -20 LED shall just turn off and the -10 LED shall just turn on.
9) Remove the DC-voltage from the side chain jack socket.
10) Repeat step 6 - 9.
(130920)