Owner manual

LYDKRAFT ApS
Mose Allé 20, DK 2610 Rødovre
Denmark
5
HIGH SHELVING:
1) Apply a signal of 20 kHz, 0,0 dBU to the input of the equalizer.
2) Turn the GAIN-control a "0". Turn the freq. switch to "4 kHz".
3) When switching between boost and cut, observe that the level is exactly the same
(<+/- 0,1dB).
Adjust with P13 located on the front PCB.
ADJUSTMENT GAIN CONTROLS IN BAND 1-3:
(THIS IS NOT VALID FOR EQ 1AM)
BAND 1, (2), >3<:
1) Apply a signal of 100Hz, (1kHz), >5kHz<, 0,0 dBU to the input of the equalizer.
2)
Turn the
GAIN
-control a "0". Turn the freq. switch to 100Hz, (1kHz), >5kHz<.
3) When switching between boost and cut, observe that the level is exactly the same
(<+/- 0,1dB).
Adjust with P4, (P7), >P10< located on the front PCB.
(
030507)