SDS
Page 2 of 7
Puffy 3D Paint –S-17-0058
5. FIRE FIGHTING MEASURES
Extinguishing Media
Suitable extinguishing media:
Water. Foam. Dry powder. Carbon dioxide (CO
2.
) Use extinguishing media
appropriate for surrounding fire.
Unsuitable extinguishing media:
None.
Protection of Firefighters
Specific hazards arising from the chemical:
No particular hazards.
Protective equipment for firefighters:
Use standard firefighting procedures and consider the hazards of
other involved materials.
Special precautions for fire fighters:
Wear full protective clothing, including helmet, self-contained
positive pressure or pressure demand breathing apparatus,
protective clothing and face mask.
Will hazardous combustion occur?:
Will not occur.
6. ACCIDENTAL RELEASE MEASURES
Personal Precautions:
Extinguish all ignition sources. Avoid sparks, flames, heat,
and smoking. Ventilate. Avoid inhalation of vapors and
contact with skin and eyes. Wear suitable protective
clothing. See Section 8 of the MSDS for Personal Protective
Equipment.
Environmental Precautions:
Do not allow to enter drains, sewer or water course.
Methods for Cleaning Up:
Clean up in accordance with all applicable regulations.
Remove sources of ignition. Absorb spillage with non-
combustible, absorbent material. Containers with collected
spillage must be properly labeled with correct contents and
hazard symbol.
Recommended Personal Protective Equipment:
See Section 8 of this SDS.
7. HANDLING AND STORAGE
Safe Storage:
Store in a cool, dry place. Keep in container closed when not in use. 40 – 100°F.
Protect from freezing.
Safe Handling:
Wash thoroughly after handling. Removing contaminated clothing and wash
before reuse. Avoid contact with eyes. Avoid ingestion and inhalation.
Known Incompatibilities:
None known.
8. EXPOSURE CONTROL AND PERSONAL PROTECTION
Occupational Exposure Limits:
Chemical name
ACGIH
OSHA PEL
NIOSH IDLH
Titanium Dioxide
13463-67-7
10 mg/m3 TWA; Appendix A4 - Not
Classifiable as a Human Carcinogen
15 mg/m3 TWA
5,000 mg/m3
Carbon Black
1333-86-4
3.5 mg/m3 TWA
(inhalable particulate matter)
TWA 3.5 mg/m3
TWA 3.5 mg/m3 Ca TWA
0.1 mg
Appropriate Engineering Controls: No special requirements under ordinary conditions of use and with adequate
ventilation.
Individual Protection measures, such as PPE (Personal Protective Equipment):
Personal Protection Equipment:
Respiratory Protection:
None required under normal handling conditions.
Eye Protection:
Wear safety glasses with side shield.