SDS
Product name: Lead-acid batteries
Revision Date: June 22, 2016 SDS No.: LAKDJH01
4
.Additional Information: The storeroom should be equipped with proper facilities for accidental leakage and fire.
8. Exposure controls/personal protection
.Occupational Exposure Limits:
Ingredients
OELs (mg/m
3
) (GBZ 2.1-2007) ACGIH TLV-TWA
MAC PC-TWA PC-STEL remark TLV-TWA remark
Lead (CAS: 7439-92-1) Not data
available
0.05mg/m
3
(dust)
0.03mg/m
3
(fume)
No data
available
G2B (Lead),
G2A (Lead
inorganic
Compounds)
0.05mg/m
3
A3
Sulfuric Acid
(CAS : 7664-93-9)
Not data
available
1mg/m
3
2mg/m
3
G1
0.2mg/m
3
(Thoracic
fraction)
A2
Note: IARC:
G1---- Carcinogenic to humans.
G2A---- Probably carcinogenic to humans.
G2B---- Possibly carcinogenic to humans.
ACGIH:
A2----Suspected human carcinogen.
A3----Confirmed animal carcinogen with unknown relevance to human.
.Monitoring Method: The hazardous substances should be monitored per GBZ 159 “Sampling code for monitoring of
hazardous substances in workplace air ". The well-accepted monitoring methods of other countries are also can be
adopted .
.Biological limit: Not data available
.Engineering Controls:
Use process enclosures, local exhaust ventilation, or other engineering controls to keep airborne levels below
recommended exposure limits.
Install washer eyes and safety showers near to the handling and storage area.
.Personal Protective Equipment (For workers) :
.Protection of Hands:
No special requirement. Recommend wearing protective gloves for industrial hygienic purpose.
.Protection of Eyes: No special requirements under normal conditions. Wear safety glasses when working in a dusty
environment.
.Respiratory Protection: No special requirements under normal conditions. Use an approved respirator if exposure limit
is exceeded or if irritation or other symptoms occur.