Safety Information

Report No.: AGC04298180501ES01
Page 37 of 51
EN 60950-1
Clause
Requirement Test
Result Remark
Verdict
ZB ANNEX (normative) SPECIAL NATIONAL CONDITIONS (EN)
1.2.4.1
In Denmark, certain types of Class I appliances (see 3.2.1.1)
may be provided with a plug not establishing earthing
conditions when inserted into Danish socket-outlets.
N
1.2.13.14
In Norway and Sweden, for requirements see 1.7.2.1 and 7.3
of this annex.
N
1.5.7.1
In Finland, Norway and Sweden, resisters bridging BASIC
INSULATION in CLASS I PLUGGABLE EQUIPMENT TYPE A
must comply with the requirements in 1.5.7.1. In addition when
a single resister is used, the resister must withstand the
resister test in 1.5.7.2.
N
1.5.8
In Norway, due to the IT power system used (see annex V,
Figure V.7), capacitors are required to be rated for the
applicable line-to-line voltage (230 V).
N
1.5.9.4
In Finland, Norway and Sweden, the third dashed sentence
is applicable only to equipment as defined in 6.1.2.2 of this
annex.
N
1.7.2.1
In Finland, Norway and Sweden, CLASS I PLUGGABLE
EQUIPMENT TYPE A intended for connection to other
equipment or a network shall, if safety relies on connection to
protective earth or if surge suppressors are connected
between the network terminals and accessible parts, have a
marking stating that the equipment must be connected to an
earthed mains socket-outlet.
The marking text in the applicable countries shall be as
follows:
In Finland: "Laite on liitettä suojakoskettimilla varustettuun
pistorasiaan"
In Norway: “Apparatet må tilkoples jordet stikkontakt”
N
1.7.2.1
(A11:2009)
In Sweden: “Apparaten skall anslutas till jordat uttag”
In Norway and Sweden, the screen of the cable distribution
system is normally not earthed at the entrance of the building
and there is normally no equipotential bonding system within
the building. Therefore the protective earthing of the building
installation need to be isolated from the screen of a cable
distribution system.
It is however accepted to provide the insulation external to the
equipment by an adapter or an interconnection cable with
galvanic isolator, which may be provided by e.g. a retailer.
The user manual shall then have the following or similar
information in Norwegian and Swedish language respectively,
depending on in what country the equipment is intended to be
used in:
N