Safety Information

Report No.: AGC04298180501ES01
Page 40 of 51
EN 60950-1
Clause
Requirement Test
Result Remark
Verdict
ZB ANNEX (normative) SPECIAL NATIONAL CONDITIONS (EN)
3.2.1.1
In Denmark, supply cords of single-phase equipment having a
rated current not exceeding13 A shall be provided with a plug
according to the Heavy Current Regulations, Section 107-2-
D1.
CLASS I EQUIPMENT provided with socket-outlets with earth
contacts or which are intended to be used in locations where
protection against indirect contact is required according to the
wiring rules shall be provided with a plug in accordance with
standard sheet DK 2-1a or DK 2-5a.
If poly-phase equipment and single-phase equipment having a
RATED CURRENT exceeding 13 A is provided with a supply
cord with a plug, this plug shall be in accordance with the
Heavy Current Regulations, Section 107-2-D1 or EN 60309-2.
N
3.2.1.1
In Spain, supply cords of single-phase equipment having a
rated current not exceeding 10 A shall be provided with a plug
according to UNE 20315:1994.
Supply cords of single-phase equipment having a rated
current not exceeding 2,5 A shall be provided with a plug
according to UNE-EN 50075:1993.
CLASS I EQUIPMENT provided with socket-outlets with earth
contacts or which are intended to be used in locations where
protection against indirect contact is required according to the
wiring rules, shall be provided with a plug in accordance with
standard UNE 20315:1994.
If poly-phase equipment is provided with a supply cord with a
plug, this plug shall be in accordance with UNE-EN 60309-2.
N
3.2.1.1
In the United Kingdom, apparatus which is fitted with a
flexible cable or cord and is designed to be connected to a
mains socket conforming to BS 1363 by means of that flexible
cable or cord and plug, shall be fitted with a „standard plug‟ in
accordance with Statutory Instrument 1768:1994 - The Plugs
and Sockets etc. (Safety) Regulations 1994, unless exempted
by those regulations.
NOTE „Standard plug‟ is defined in SI 1768:1994 and
essentially means an approved plug conforming to BS 1363 or
an approved conversion plug.
N
3.2.1.1
In Ireland, apparatus which is fitted with a flexible cable or
cord and is designed to be connected to a mains socket
conforming to I.S. 411 by means of that flexible cable or cord
and plug, shall be fitted with a 13 A plug in accordance with
Statutory Instrument 525:1997 - National Standards Authority
of Ireland (section 28) (13 A Plugs and Conversion Adaptors
for Domestic Use) Regulations 1997.
N
3.2.4
In Switzerland, for requirements see 3.2.1.1 of this annex.
N
3.2.5.1
In the United Kingdom, a power supply cord with conductor
of 1,25 mm2 is allowed for equipment with a rated current over
10 A and up to and including 13 A.
N