Safety Information

Report No.: AGC04298180501ES01
Page 41 of 51
EN 60950-1
Clause
Requirement Test
Result Remark
Verdict
ZB ANNEX (normative) SPECIAL NATIONAL CONDITIONS (EN)
3.3.4
In the United Kingdom, the range of conductor sizes of
flexible cords to be accepted by terminals for equipment with a
RATED CURRENT of over 10 A up to and including 13 A is:
• 1,25 mm
2
to 1,5 mm
2
nominal cross-sectional area.
N
4.3.6
In the United Kingdom, the torque test is performed using a
socket outlet complying with BS 1363 part 1:1995, including
Amendment 1:1997 and Amendment 2:2003 and the plug part
of DIRECT PLUG-IN EQUIPMENT shall be assessed to BS
1363: Part 1, 12.1, 12.2, 12.3, 12.9, 12.11, 12.12, 12.13, 12.16
and 12.17, except that the test of 12.17 is performed at not
less than 125 °C. Where the metal earth pin is replaced by an
Insulated Shutter Opening Device (ISOD), the requirements of
clauses 22.2 and 23 also apply.
N
4.3.6
In Ireland, DIRECT PLUG-IN EQUIPMENT is known as plug
similar devices. Such devices shall comply with Statutory
Instrument 526:1997 - National Standards Authority of Ireland
(Section 28) (Electrical plugs, plug similar devices and sockets
for domestic use) Regulations, 1997.
N
5.1.7.1
In Finland, Norway and Sweden TOUCH CURRENT
measurement results exceeding 3,5 mA r.m.s. are permitted
only for the following equipment:
• STATIONARY PLUGGABLE EQUIPMENT TYPE A that
is intended to be used in a RESTRICTED ACCESS
LOCATION where equipotential bonding has been applied, for
example, in a telecommunication centre; and
has provision for a permanently connected PROTECTIVE
EARTHING CONDUCTOR; and
is provided with instructions for the installation of that
conductor by a SERVICE PERSON;
• STATIONARY PLUGGABLE EQUIPMENT TYPE B;
• STATIONARY PERMANENTLY CONNECTED EQUIPMENT.
N
6.1.2.1
(A1:2010)
In Finland, Norway and Sweden, add the following text
between the first and second paragraph of the compliance
clause:
If this insulation is solid, including insulation forming part of a
component, it shall at least consist of either
- two layers of thin sheet material, each of which shall pass the
electric strength test below, or
- one layer having a distance through insulation of at least 0,4
mm, which shall pass the electric strength test below.
Alternatively for components, there is no distance through
insulation requirements for the insulation consisting of an
insulating compound completely filling the casing, so that
CLEARANCES and CREEPAGE DISTANCES do not exist, if
the component passes the electric strength test in accordance
with the compliance clause below and in addition
N