Safety Information

Report No.: AGC04298180501ES01
Page 9 of 51
EN 60950-1
Clause
Requirement Test
Result Remark
Verdict
2.1.1.8
Energy hazards d.c. mains supply
Not directly connect to mains supply
N
a)Capacitor connected to the d.c. mains supply .. :
N
b)Internal battery connected to the d.c. mains
supply ................................................................... :
N
2.1.1.9
Audio amplifiers .................................................... :
No any amplifiers
N
2.1.2
Protection in service access areas
N
2.1.3
Protection in restricted access locations
N
2.2
SELV circuits
P
2.2.1
General requirements
42.4V peak or 60VDC are not
exceeded in SELV circuit under
normal operation or single fault
condition.
P
2.2.2
Voltages under normal conditions (V) .................. :
Within SELV limits.
P
2.2.3
Voltages under fault conditions (V) ...................... :
Within SELV limits.
P
2.2.4
Connection of SELV circuits to other circuits ....... :
N
2.3
TNV circuits
N
2.3.1
Limits
No TNV circuits.
N
Type of TNV circuits ............................................. :
N
2.3.2
Separation from other circuits and from accessible
parts
N
2.3.2.1
General requirements
N
2.3.2.2
Protection by basic insulation
N
2.3.2.3
Protection by earthing
N
2.3.2.4
Protection by other constructions ......................... :
N
2.3.3
Separation from hazardous voltages
N
Insulation employed .............................................. :
N
2.3.4
Connection of TNV circuits to other circuits
N
Insulation employed .............................................. :
N
2.3.5
Test for operating voltages generated externally
N
2.4
Limited current circuits
N
2.4.1
General requirements
No limited current circuits to be
evaluated.
N
2.4.2
Limit values
N
Frequency (Hz) ..................................................... :
N