Installation Manual

Quick Installation Guide
VDSL2 (Profile 30a) Industrial Ethernet Extender
DIP 1 DIP2 DIP3 DIP4
Side VDSL Profile Rate Limit SNR
OFF OT 30a Symmetric 9dB
ON RT 17a Asymmetric 6dB
Description
DIP 1
OTLAN Extender acts as Central Office (CO) side.
RTLAN Extender acts as Customer Premise Equipment (CPE)
side.(Default)
DIP 2
30aVDSL High Speed Mode.(Default)
17aVDSL Long Reach Mode.
DIP 3
SymmetricSupport the band plan G.997 and provide the symmetric
transmission on both downstream and upstream.
AsymmetricProvides highest line rate in short range in asymmetric
mode.
DIP 4
9dBBetter channel noise protection with SNR up to 9 dB.
6dBOriginal channel noise protection with 6 dB SNR.
LED Blink ON OFF
PWR
(Green)
Device Power
ON
Device Power
OFF
LNK
(Green)
Slow: Idle
Fast: Training /
Data Transmitting
Link Up Link Down
RT
(Green)
CPE CO
LEDs for VDSL
LEDs for LAN
LED Blink ON OFF
LNK
(Green)
Activity Link Up Link Down
FUL
(Green) Full Duplex Half Duplex
SP
(Green)
100Mbps 10Mbps
** Power supply:
12 Vdc over 2.1mm DC Jack . (External Power Adaptor included)
<Quick Installation>
STEP 1
Set the LAN extender to CO mode or
CPE mode from the DIP switch at the
front panel. For Point to Point
applications, one unit must be Master
(CO mode) and the other one is Slave
(CPE mode).
STEP 2
Connect the LAN extender (CPE) with a
regular Cat. 5 cable to the LAN port
from a PC or another device on LAN.
STEP 3
Power on LAN extender (CPE) by
connecting the power adapter.
STEP 4
Connect the CPE and CO via a regular
Cat. 5 cable or a telephone wire from
each VDSL2 port.
STEP 5
Connect the LAN extender (CO) with a
regular Cat. 5 cable to the LAN port and
then connect the other end of the RJ45
cable to the service equipment.
STEP 6
Power on LAN extender (CO) by
connecting the power adapter and then
observe the status of VDSL link LED.
+
Setting as CO side
Setting as CPE side