Use and Care

8
INNER TEMPERATURE DISPLAY
UP/DOWN BUTTON (Temperature control button)
INNER TEMPERATURE DISPLAY
FAN RUNNING
1. Evaporator fan motor is activated when the door (both doors for M3F47-2, M3F47-4,
all three doors for M3F72-3, M3F72-6) is closed.
1.
By pushing the up/down button, you can set the inside temperature level from ‘1’ to ‘7’.
2.
If you want lower temperature, push the Down button to be lighted higher level numbers.
1.
Press the down ( ) buttom 5 times while pressing up ( ) button, the Defrost will start.
2. During the Manual Defrost mode, the Up/Down button for the temp, control can not make
the compressor cycle ON or OFF.
DEFROST
1.
The electronic defrost controller is set at the factory to provide a defrost cycle every 6
hours (4 times per a day).
2.
If it is necessary to change the intervals of defrost due to unusual operating conditions,
it can be accomplished by adjusting the switch which is located on the inside of
the top grille.
3. The panel displays “ ” during the defrost cycle.
1. It displays the inside temperature.
2. Display range is -50˚F to 50˚F (-45˚C ~ +10˚C).
3. When the inside temperature is lower than -50˚F, the panel will display ʻ ʼ.
and, higher than 50˚F, the panel will display ʻ ʼ.