250 Victoria Street CARSON, CA 90746 T E L : 310-900-1000 FAX : 310-900-1077 Toll Free : 1-800-627-0032 (U.S.A and Canada) http://www.turboairinc.
Turbo air Speeds UP the Pace of Innovation COMMERCIAL REFRIGERATOR Installation and Operation Manual Please read this manual completely before attempting to install or operate this equipment! SAK-50 SAK-60 SAK-70
Turbo air Speeds UP the Pace of Innovation CONTENTS INTRODUCTION 1 SPECIFICATION 3 INSTALLATION INSTRUCTIONS 3~4 Inspection for damage Location of Display Leveling of Display OPERATING INSTRUCTIONS 5 Power input/output Thermometer How to place product MAINTENANCE & CLEANING 6~8 Interior/Exterior cleaning Drain pipe cleaning Condenser coil TROUBLE SHOOTING 8 Display not working Display case warm WIRING DIAGRAM WARRANTY STATEMENT 9 9~13
Turbo air Speeds UP the Pace of Innovation INTRODUCTION This owner’s manual has important information. Please read the entire manual before installing your new Turbo Air Open Display Merchandiser. After reading manual if you have any questions, please fill free to call: “R”or“L”on the model name designates the location of the compressor in the unit. CUSTOMER SERVICE DEPARTMENT TURBO AIR 1250 VICTORIA ST.
Turbo air Speeds UP the Pace of Innovation WARNING! Failure to read this manual completely can result in personal injury or damage to the unit. Keep manual in a safe place to refer to in the future. Display should be on dedicated outlet for proper operation.
Turbo air Speeds UP the Pace of Innovation SPECIFICATION Model Dimension (W×D×H)in SAK-50* 3A Compressor 120V/1Ph/60Hz 3A 3A SD152C-L1U2 Refrigerant Weight of Case SAK-70* 48.8×14.2×11.5 60.3×14.2×11.5 71.8×14.2×11.5 Electricity Power Input SAK-60* 76.06 lbs R-134a 87.08 lbs 98.01 lbs INSTALLATION INSTRUCTIONS INSPECTION FOR DAMAGE Customer is responsible for checking for damage. First inspect crate as soon as it arrives.
Turbo air Speeds UP the Pace of Innovation LOCATION OF DISPLAY CASE MERCHANDISER Display is designed to be in an ambient 75 degrees Fahrenheit (dry bulb) or colder and 55 percent relative humidity. If unit is installed in a warm ambient Display will not cool effectively. Move the display to the final location before removing shipping skid. Allow 3 inches from back of Display to wall. Condenser is located in beside of Display. Do not block inlet /outlet. LEVELING OF DISPLAY CASE MERCHANDISER a.
Turbo air Speeds UP the Pace of Innovation OPERATING INSTRUCTIONS POWER INPUT/OUTPUT a. After installing unit and all electrical to the Display, Display is ready to start up. b. Input is controlled by pushing the button. iii Apporx 30min interval is needed to reactivate display case after power off. THERMOMETER : Thermometer showing temperature is located on opposite side of machine room. NOTE: Before placing products to Display wait for unit to reach desired temperature.
Turbo air Speeds UP the Pace of Innovation MAINTENANCE & CLEANING INTERIOR/EXTERIOR CLEANING a. Always before cleaning Display, Remove products and unit should be turned off at power switch b. Do not wet electrical components. c. Do not use water jet to clean the exterior. DRAIN PIPE CLEAINING a. Either mix 0.26 gal(1liter) of water with 0.13fl.Oz(3.7ml) of 5.25% sodium hypochlorite in a suitable container. b. Join the drain hose and turn up the end of hose above display case c.
Turbo air Speeds UP the Pace of Innovation DISPLAY CASE SHOULD BE CLEANED THOROUGHLY BEFORE FIRST USE. a. Do not clean with harsh detergents. Use a mild soap b. Remove all products. c. Remove bottom trays. d. Clean interior with warm water and mild detergent. e. Wipe with soft cloth soaked in warm water. Do not leave residue of soap. CONDENSER COIL ! How to remove Louver 1. Disconnect the electrical power to the unit 2. Lift up the Louver to release the Louver from the body.
Turbo air Speeds UP the Pace of Innovation 3. Pull the Louver toward you.(②) 4. Pull on the downward. (③) 5. Brush the dirt, lint, etc from the finned condenser coil. 6. When finished, Louver installed by reverse way of removing 7. Reconnect the electrical power to the unit. 8. Condenser should be cleaned every 1 months or as needed. EVAPORATOR COIL 1. Remove the glass door and Boottom shelf.(①) 2. Join the drain hose.(②) 3. Sweep evaporator pins with warm water and brush. 4.
Turbo air Speeds UP the Pace of Innovation WIRING DIAGRAM WARRANTY STATEMENT Warranty claims All claims for labor or parts must be made directly through Turbo Air. All claims should include:model number of the unit, the serial number of the cabinet, proof of purchase, date of installation, and all pertinent information supporting the alleged defect. In case of compressor replacement under warranty, either compressor or compressor tag must be returned to Turbo Air along with above listed infomation.
Turbo air Speeds UP the Pace of Innovation One Year Parts & Labor Warranty Turbo Air warrants all new refrigerated components, the cabinet and all parts, to be free from defects in materials or workmanship, under normal and proper use and maintenance service as specified by Turbo Air and upon proper installation annd startup in accordance with the instruuction packet supplied with each Turbo Air unit.
Turbo air Speeds UP the Pace of Innovation metering device,m driers, motoir starting equipment, fan assembly or and other electrical components, etcetera. 404A / 134A Compressor warranty The four-year compressor warranty detailed above will be void if the following Procedure is not carefully adhered to: 1. This system contains R404A or R134A refrigerant and polyol ester lubricant. The polyol ester lubricant has rapid moisture absorbing qualities. 2.
Turbo air Speeds UP the Pace of Innovation RESULT FROM REFRIGERATION FAILURE. WARRANTY IS NOT TRANSFERABLE. This warranty is not assignable and applies only in favor of the original purchaser / user to whom delivered. ANY SUCH ASSIGNMENT OR TRANSFER SHALL VOID THE WARRANTIES HEREIN AND SHALL VOID ALL WARRANTIES, EXPRESS OR IMPLIED, INCLUDING ANY WARRANTY OF MERCHANTABILITY OR LABOR COVERAGE FOR COMPONENT FAILURE OR OTHER THE WARRANTY PACKET PROVIDED WITH THE UNIT.
Turbo air Speeds UP the Pace of Innovation responsible for, any warranty claims made on products sold or used ouutside the continent of the United States and Canada.