COMMERCIAL REFRIGERATOR INSTRUCTION MANUAL Model No.: TGM-50RS TGM-72RS FEATURE CHART Before operating this unit, please read these instructions completely.
HOW TO INSTALL ■ In good ventilation. • Place the refrigerator in well ventilated area for better cooling. ■ Place the refrigerator on hard and level floor. • Unlevel floor may cause the refrigerator to make noise. ■ Put away heat source from the refrigerator. • High ambient temperature will make cooling efficiency lower. ■ Install the refrigerator indoor do not get unit wet. • This unit is designed for indoor usage only. ■ Avoid places that are exposed to smoke.
CLEANING ■ Caution • Unplug the power cord before cleaning. • Clean the refrigerator periodically. • Do not use the abrasive cleaners, solvents or polishing agents on plastic parts. These cleansers may cause cracking or discoloring. ■ Cleaning the interior and exterior • Wash it with warm and soapy water and rinse, and dry it. • Wash the shelf with water. • Dewdrops in rainy-season, wipe it with a dry cloth. ■ Check points after cleaning • Check again the refrigerator for safety.
CAUTION ■ Ventilation - Place the refrigerator under proper ventilation - Keep the cabinet 4” from rear wall. ■ Warning - It is the responsibility of the purchaser in case of followings. • Compressor under low voltage • Compressor more than 7 feet from plug-in connection. • Compressor under unstable voltage • Compressor not under 115V/60Hz ■ Start-up - Plug the power cord into the wall outlet. - The outlet should be only for the refrigerator. - The temperature controller should be on normal position.
BEFORE REQUESTING SERVICE SYMPTOMS CAUSES SOLUTIONS • Because of the differences between ambient temperature and a quantity of food stored, when the temp. dial is on the cold position. • Turn the temp. dial to the cool position. • Food would freeze in ambient temperature of below 41°F and the temp. dial on the cold position. • Turn the temp. dial to the cool position. When the refrigerator does not refrigerate at all. • When there is a power connection or failure problem.
MANUFACTURING COMPANY ONE YEAR WARRANTY Turbo air warrants to the original purchaser of every new Turbo air refrigerated unit, the cabinet and all parts thereof, to be free from defects in material or workmanship, under normal use and service, for a period of one(1) year from the date of original installation or 15 months after shipment date from Turbo air , whichever occurs first.
WHAT IS NOT COVERED BY THIS WARRANTY Turbo air’s sole obligation under this warranty is limited to either repair or replacement of parts, subject to the additional limitations below. This warranty neither assumes nor authorizes any person to assume obligations other than expressly covered by this warranty. 1. WARRANTY IS NOT TRANSFERABLE. This warranty is not assignable and applies only in favor of the original purchaser/user to whom delivered.