Turbo Air Speeds up the Pace of Innovation Open Display Merchandiser Installation and Operation Manual Please read this manual completely before attempting to install or operate this equipment. Horizontal Open Display Cases TOM-30L*-**-* TOM-40L*-**-* TOM-50L*-**-* TOM-60L*-**-* TOM-75L*-**-* TOM-30S*-**-* TOM-40S*-**-* TOM-50S*-**-* TOM-60S*-**-* TOM-75S*-**-* TOM-W-30S*-**-* TOM-W-40S*-**-* TOM-W-50S*-**-* TOM-W-60S*-**-* TOM-W-75S*-**-* www.turboairinc.
CONTENTS PAGE INTRODUCTION 3 SPECIFICATIONS 4 INSTALLATION Damage inspection 5 Location of display Leveling of display TURBO AIR RECOMMENDED OPERATING CONDITIONS 6 OPERATING INSTRUCTIONS 7 Power switch Light switch Temperature control Thermometer Placing the product MAINTENANCE & CLEANING 8 Condenser coil TROUBLESHOOTING 9 Merchandiser not functioning Merchandiser is warm Lights are not working WIRING DIAGRAM 10 WARRANTY 11 - 13 2
INTRODUCTION This owner’s manual has important information. Please read the entire manual before installing your new Turbo Air Open Display Merchandiser. For specific questions not answered on this manual, please call: CUSTOMER SERVICE DEPARTMENT TURBO AIR 4184 E. Conant St. Long Beach, CA 90808 1-800-381-7770 Please write down the model and serial number of your merchandiser for future references: MODEL NUMBER SERIAL NUMBER WARNING Keep this manual in a safe place for your reference.
SPECIFICATIONS Model TOM-30L*-**-* TOM-40L*-**-* Dimension (W x D x H) in. 28 x 34.6 x 45.8 39 x 34.6 x 45.8 50.8 x 34.6 x 45.8 63.2 x 34.6 x 45.8 75.6 x 34.6 x 45.8 Electricity TOM-60L*-**-* TOM-75L*-**-* 120V/1PH/60HZ Full Load Amperes 7.5A Compressor HK6A1C2U 11A 11A CAJ4476Y, NT6217Z Refrigerant Lighting TOM-50L*-**-* 15.5A 15.5A CAJ4492Y, NJ6220Z R-134A 7.2W X 2 10.8W X 2 14.4W X 5 Defrost 18.0W X 5 21.6W X 5 448 lbs. 507 lbs. Timed off defrost Net Weight 257 lbs.
INSTALLATION INSTRUCTIONS DAMAGE INSPECTION Prior to installation, the customer must check for damages with the freight company before the unit is accepted. 1. If the crate is damaged, make sure to note the damage on the Bill of Lading prior to signing the delivery off. 2. Concealed damage must be reported within 24 hours of receiving the unit. Bill of Lading must be faxed to the Claims department. Pictures of both unit and crating may be requested.
TURBO AIR RECOMMENDED OPERATING CONDITIONS • Unit should not be placed in direct sunlight. • Unit should not be placed near HVAC vents. • Unit should not be placed near doorways. • Unit should not be placed near fans. • Level the cabinet on all four corners of the base. • Operating environment not to exceed 75ºF (23ºC) and 55% humidity. • Do not load product beyond the edge of the shelf • Confirm there is enough clearance for proper air circulation.
OPERATING INSTRUCTIONS Level and set your merchandiser in place. Connect all necessary electrical connections. Your Open Display Merchandiser should now be ready for use. POWER SWITCH: Located at the bottom of front panel, colored in red. LIGHT SWITCH: Located at the bottom of front panel, colored in green. TEMPERATURE CONTROL: The temperature control is located underneath the bottom shelf and near the inner right-hand side of your merchandiser. 1. The default setting for the control is Normal. 2.
MAINTENANCE & CLEANING Always turn off your unit (both power and lights) when cleaning. Remove all products and allow your unit to reach room temperature. Do not allow electrical components to get wet. CLEAN YOUR OPEN DISPLAY MERCHANDISER THOROUGHLY BEFORE FIRST USAGE. a. Do not clean with harsh detergents. Use mild soap. b. Remove all products. c. Remove shelves and bottom trays. d. Clean interior with warm water and mild detergent. e. Wipe with damp cloth. Do not leave soap residue.
TROUBLESHOOTING For any problems with your unit, please refer to the following check list. If you are still experiencing problems or have questions, please call the Customer Service line at 1-800-381-7770. Ⅰ. MERCHANDISER NOT FUNCTIONING a. Check to see that the breaker hasn’t tripped. b. Check that enough power is BEING supplied to the unit. c. Check that the power switch is on. Ⅱ. MERCHANDISER IS WARM a. Check the condenser to see if it is clean. b.
WIRING DIAGRAM timer 10
MANUFACTURING COMPANY TWO YEAR WARRANTY Turbo Air warrants to the original purchaser of every new Turbo Air refrigerated unit, the cabinet and all parts thereof, to befree from defects in material or workmanship, under normal use and service, for a period of two (2) year from the date of original installation or 27 months after shipment date from Turbo Air , whichever occurs first.
What is NOT covered by this warranty Turbo Airʼs sole obligation under this warranty is limited to either repair or replacement of parts, subject to the additional limitations below. This warranty neither assumes nor authorizes any person to assume obligations other than expressly covered by this warranty. 1. WARRANTY IS NOT TRANSFERABLE. This warranty is not assignable and applies only in favor of the original purchaser/user to whom delivered.
Warranty Claims... All claims for parts or labor must be made directly thorough Turbo Air. All claims should include: model number of the unit, the serial number of the cabinet, proof of purchase, date of installation, and all pertinent information supporting the alleged defect. In case of compressor replacement under warranty, either compressor or compressor tag must be returned to Turbo Air along with above listed information. Failure to comply with warranty policies will result in voiding claims.