Fullrange Subwoofer Function
FBQ
Auto Auto
Automatically sets as many fi lters as
required. Whenever a new feedback
frequency is discovered, the fi rst fi lter
will be released to attenuate the new
frequency, and so forth.
Single Single
Activates the FBQ (feedback detection)
functionality, up to 8 feedback fi lters.
Learn Learn
Automatic procedure which searches
for feedback frequencies and locks
settings after all 8 fi lters have been set.
WARNING!
Please use ear protection during this
procedure. The feedback signal may
approach the system’s maximum level,
which may cause hearing damage!
Reset Reset
Resets all fi lters.
SETUP
(page 1)
INPUT
Input Input
Lets you choose the audio input
source. Chose between Local
(Analogue Input) or ULTRANET
(e.g., P16 monitoring system or
M32 audio via ULTRANET).
Trim Trim
Adjusts the input gain of the
ULTRANET digital inputs in a range
fm +10 dB to - 30 dB
Remote Remote
Enables ULTRANET remote control
functionality in order to protect
against misuse.
VU VU
Displays the respective input level
of all 16 channels receiving via
ULTRANET; only visible when
ULTRANET input is selected.
POSITION
Stand Floor
For positioning the speaker on a pole
mount stand (fullrange) or on the fl oor
(subwoofer).
Wall Wall
For positioning the speaker on or next
to a wall (fi xed install); alternatively as
a monitor speaker (wedge).
Ceiling —
For positioning the speaker on a wall
next to the ceiling (fi xed install).
Corner Corner
For positioning the speaker in a corner
next to the ceiling (fi xed install);
For positioning the speaker in a corner
(subwoofer).
DELAY
Delay Delay
Adjusts the amount of delay (max
300msec = 103.08m or 338.19 feet).
Unit Unit
Selects between msec, meter and feet.
LIMITER
Limit Limit
Adjust the limiter threshold for the
input signal (from OFF up to -30 dB).
This threshold adjustment allows
you to set a max output power
which is below the iQ system’s rated
max output.
Fullrange Subwoofer Function
SETUP
(page 2)
Version Version
Displays the installed fi rmware version.
LOAD
1. - 20. 1. - 20.
To load a specifi c preset, turn the
encoder to select the desired peset’s
number, and then either the ENTER
button or the encoder. When asked
to confi rm press the encoder again or
EXIT to abort.
SAVE
1. - 20. 1. - 20.
To save a preset choose the respective
preset slot and press ENTER or
the encoder.
Sub Menu
Save Preset Save Preset
Name the preset by choosing the
characters with the encoder and
pressing to confi rm each character.
When fi nished, press the ENTER
button to save the preset.
Setup
Contrast Contrast
Adjust LCD panel contrast.
The default contrast value is 15.
Screen Screen
ON: LCD screen saver (default)
turns on automatically after
approx. 2 minutes.
OFF : LCD turns off automatically after
approx. 5 minutes.
Logo Logo
OFF: Deactivates front panel
logo illumination.
ON: Activates front panel
logo illumination.
LIMIT: Logo will light up when the
limiter is active.
SETUP
Sub Menu
Lock Lock
Lock the device and creat a password
by choosing the password characters
with the encoder and pressing to
confi rm each character. When fi nished
press the ENTER button. Unlock the
device by entering the password or
connecting the unit via USB to a PC
running iQ software. The software
does not require a password.
Warning Warning
In case of overheating, an alert appears
on the LCD screen, and the amplifi er
will shut down until the unit cools.
LCD Graphic Indicators
To help the user immediately recognize that a parameter has been selected and changed from the initial
default setting, the parameter’s related text on the top-level screen will invert and change to black text on a
white background. As an example, the following screenshots show how the text for the MODEL function
changes when the iQ8 default sound has been changed to the modeled PS8 sound:
This indicator function occurs only on the main DSP menu level and works for all DSP-related functions,
except for the LOAD, SAVE and SETUP sub-sections on the second page of the top-level SETUP menu.