28 MANCHESTER SERIES Rigging Manual
3.0.1 Required Components
Item Quantity
MAN-FG Fly Grid 1
MV212 Cabinet 16 (maximum at 10:1 Safety Factor)
3.0.2 Preparation
Use the EASE FOCUS software application to design your system to suit the venue.
This will calculate which y grid mounting hole to attach your bow shackle, and
at which angle to set each MV212 cabinet to achieve optimum coverage.
3.0.3 Location
Move the rst MV212 cabinet so it is sitting upright on a safe at surface,
directly below the suspension point.
3.0.4 Measured Weights
Item Quantity Weight
MAN-FG with Tip Bar 1 53 kg 116.9 lbs
MV212 1 53 kg 116.9 lbs
MV212-XV 1 50 kg 110.2 lbs
3.0.5 MAN-FG Fly Grid WLL (10:1 Safety Factor)
Item Working Load Limit (WLL) 3 Point Suspension
MAN-FG 894 kg 1971 lbs
Chapter 3: Assembling an MV212 Array on a MAN-FG Fly Grid
The following procedure shows how to build an array of MV212 cabinets by
adding them one at a time.
Alternatively, cabinets can be pre-assembled into groups of four, and then
connected to the y grid at a later time. This method is shown in procedure 3.2.
The system is suspended using a MAN-FG y grid that attaches to your
lifting system.
The top MV212 cabinet connects to two front mounting points on the y grid,
and one rear mounting point.
There are 9 rear mounting holes on the back of the MV212 that allow the cabinet
angle to be selected from 0 to 10 degrees.
! WARNING
DO NOT EXCEED A TOTAL QUANTITY OF 16 MV212 CABINETS FOR ONE MAN-FG
FLY GRID. FAILURE TO FOLLOW INSTRUCTIONS MAY CAUSE PERMANENT INJURY
OR DEATH.
3.0.6 Personnel
The following procedures shall be undertaken by experienced, certied,
qualied, and authorised personnel only. The procedures require the use of three
or more authorised persons.
Protective Headwear shall be worn
Protective Footwear shall be worn
Protective Gloves shall be worn
Protective Eyewear shall be worn
Practice Safe Lifting