Quick Start Guide
12 MANCHESTER Series Quick Start Guide 13
MOM: Output Patching (DSP Module Output to Amplier ChannelInput)
1. Click “I/O Cong &Worksheets”
2. To patch outputs, click on the “Modules” button.
3. Select the rst MV212 Module, Click “I/O Cong &Worksheets”
Click on the magnifying glass at the output side of the DSP block diagram in the right of thescreen.
The Patch screen may be all blue or may have some pre-dened selection in orange – make sure none are patched (so all numbered icons areblue)
Assign the LF to its dedicated output section, while the MF and HF must both be assigned at the same output asshown.
Note the Yellow notice: ”OUTPUT MIXINGACTIVE”
Please pay attention to MOM, for example, in the diagram below, you can see that both the mid and high output bands of the DSP are patched to the same output
number2.
MS215 and MS218 subwoofers each have 2 individual base pre-sets: forward ring andcardioid.
Warning: Do not combine MS215 and MS218 subwoofers on the same amplier / DSPcircuit.