User's Manual
Table Of Contents
- Important Safety Instructions
- Legal Disclaimer
- Limited warranty
- Chapter 1: Safety Information
- Chapter 2: Introduction
- Chapter 3: Assembling an MV212 Array on a MAN-FG Fly Grid
- Chapter 4: Assembling MS215 Subwoofers on a MAN-FG Fly Grid
- Chapter 5: Assembling an MV212 Array with a MS215 Subwoofer
- Chapter 6: Groundstack of two MS215 Subwoofers
- Chapter 7: Groundstack MS215 Subwoofer and MV212 Array
- Chapter 8: MV212-VT and MS215-VT Vertical Transporters
- Chapter 9: Safety Inspection
- Chapter 10: Enclosure quantities and combinations for MAN-FG fly grid suspension at 10:1, 7:1, and 5:1 design factors
42 MANCHESTER SERIES Rigging Manual
Chapter 7: Groundstack MS215 Subwoofer and MV212 Array
7.0.1 Required Components
Item Quantity
MS215 Subwoofer 3 X MS215
MV212 Cabinet 6 X MV212
7.0. 2 Location
The MS215 subwoofer should be located on a at, horizontal, and dry surface,
capable of supporting the weight of the complete assembly.
7.0. 3 Measured Weights
Item Quantity Weight
MAN-FG 1 53 kg 116.9 lbs
MV212 1 53 kg 116.9 lbs
MS215 1 83 kg 183 lbs
The following procedure describes how to assemble a groundstack with a MS215
subwoofer as a base, and an array of four MV212 cabinets on top.
WARNING
DO NOT EXCEED A TOTAL QUANTITY OF 6 x MV212 CABINETS FOR THIS
GROUNDSTACK CONFIGURATION. FAILURE TO FOLLOW INSTRUCTIONS MAY CAUSE
PERMANENT INJURY OR DEATH.
WARNING
WHERE POSSIBLE ALWAYS SECURE THE GROUNDSTACKED SPEAKERS TO THE
STACKING SURFACE WITH ADDITIONAL FIXINGS SUCH AS RATCHET STRAPS.
7.0.4 Personnel
The following procedures shall be undertaken by experienced, certied,
qualied, and authorised personnel only. The procedures require the use of three
or more authorised persons.
Protective Headwear shall be worn
Protective Footwear shall be worn
Protective Gloves shall be worn
Protective Eyewear shall be worn
Practice Safe Lifting