Quick Start Guide
22 TBV-AN BERLIN SERIES Quick Start Guide 23
TBV-AN DSP Menu Structure
Fullrange Subwoofer Function
PROCESS
EQ
1-Box None
For single TBV123-AN enclosure. Can be used in LONG or
SHORT THROW mode, depending on the application.
2-Box —
Includes equalization to compensate for low frequency
coupling of 2 x TBV123-AN enclosures. Provides matched
sensitivity with nominal at frequency response under
freeeld conditions in SHORT THROW mode. Can also be
used in LONG THROW mode depending on the application.
3-Box —
Includes equalization to compensate for low frequency
coupling of 3 x TBV123-AN enclosures. Provides matched
sensitivity with nominal at frequency response under
freeeld conditions in SHORT THROW mode. Can also be
used in LONG THROW mode depending on the application.
User User
Lets you dene your own frequency response setting by
entering the corresponding sub-menu.
Sub menu
Low/ High Shelving Low/ High Shelving Lets you dene a low and high shelving lter.
Parametric 1 & 2 Parametric 1 & 2
Lets you dene a parametric bell-type EQ
(Frequency, Qual. and Gain).
XOVER
FULL — Unit is set for default full-range reproduction.
HP 120 Hz —
Preset with 120 Hz 24 dB / octave high pass lter.
For use with TBV118L-AN in LP 120 mode
User —
User crossover sub menu for combination with
other subwoofer speaker systems
XOVER
— LP 80
Preset with 80 Hz 24 dB / octave low pass lter for
TBV118L-AN (front-ring).
CARDIO
Cardioid preset with 80 Hz 24 dB / octave low pass
lter for TBV118L-AN (rear-ring). For use with
TBV118L-AN (front-ring) in LP 80 mode with 2:1
cabinet ratio (front-ring : rear-ring)
LP 120
Preset with 120 Hz 24 dB / octave low pass lter for
TBV118L-AN (front-ring). For use with TBV123-AN in
HP 120 mode.
CARDIO
Cardioid preset with 120 Hz 24 dB / octave low pass lter
for TBV118L-AN (rear-ring). For use with TBV118L-AN
(front-ring) in LP 120 mode with 2:1 cabinet ratio
(front-ring : rear-ring)
Sub Menu
Freq Freq
Select the desired crossover frequency:
• For Fullrange Systems: 55 Hz to 400 Hz.
• For Subwoofer Systems: 50 Hz to 150 Hz.
Phase Phase Adjust the absolute polarity (0° or 180°).
FBQ
Auto Auto
Automatically sets as many lters as required. Whenever a
new feedback frequency is discovered, the rst lter will be
released to attenuate the new frequency, and so forth.
Single Single
Activates the FBQ (feedback detection) functionality,
up to 8 feedback lters.
Learn Learn
Automatic procedure which searches for feedback
frequencies and locks settings after all 8 lters have
been set.
WARNING!
Please use ear protection during this procedure.
The feedback signal may approach the system's
maximum level, which may cause hearing damage!
Reset Reset Resets all lters.
Fullrange Subwoofer Function
SETUP
INPUT
Input Input
Lets you choose the audio input source. Choose between
Local (analogue input) or ULTRANET (e.g., P16 monitoring
system or M32 audio via ULTRANET).
Volume Volume
Adjusts the input gain. With ULTRANET digital inputs over
a range from + 10 dB to - 30 dB. With analogue input from
0 dB to - ∞ dB.
Sensitivity Sensitivity
Adjusts input sensitivity for maximum output. When using
an analogue source +4 dBu for normal operation, +14 dBu
for high level input.
Short Throw —
Nominal-at low and high frequency response under
freeeld conditions. Suitable for 1-3 TBV123-AN enclosures
when used for short throw applications including:
distributed front ll, stereo inll, under-balcony ll and
stacked, tripod-mounted or pole-mounted systems for short
throw front-of-house or sidell stage monitoring.
Long Throw —
For medium- to long-throw applications. Suitable for
suspended arrays consisting of 1-3 TBV123-AN enclosures.
High-frequency shelving pre-emphasis compensates for air
absorption over typical throw distances and is combined
with low frequency shelving to provide an enhanced
LF contour.
DELAY
Delay Delay
Adjusts the amount of delay
(max 300msec = 103 m or 338 feet).
Unit Unit Selects between msec, meters and feet.
LIMITER
Limit Limit
Adjust the limiter threshold for the input signal
(from OFF up to -30 dB). This threshold adjustment
allows you to set a max output power which is below the
loudspeaker system's rated max output.
SETUP
Version Version Displays the installed rmware version.
LOAD
1. - 20. 1. - 20.
To load a specic preset, turn the encoder to select the
desired preset's number, and then press either the ENTER
button or the encoder. When asked to conrm press the
encoder again or EXIT to abort.
SAVE
1. - 20. 1. - 20.
To save a preset choose the respective preset slot and
press ENTER or the encoder.
Sub Menu
Save Preset Save Preset
Name the preset by choosing the characters with
the encoder and pressing to conrm each character.
When nished, press the ENTER button to save the preset.
SETUP
Contrast Contrast Adjust LCD panel contrast. The default contrast value is 15.
Screen Screen
ON: LCD screen saver (default) turns on automatically
after approx. 2 minutes.
OFF : LCD turns o automatically after approx. 5 minutes.
Sub Menu
Lock Lock
Lock the device and create a password by choosing the
password characters with the encoder and pressing to
conrm each character. When nished press the ENTER
button. Unlock the device by entering the password or
connecting the unit via USB to a PC running proprietary
remote software. The software does not require a password.
Warning Warning
In case of overheating, an alert appears on the LCD screen,
and the amplier will shut down until the unit cools