Rigging Manual
Table Of Contents
- Important Safety Instructions
- Legal Disclaimer
- Limited warranty
- Chapter 1: Safety Information
- Chapter 2: Introduction
- Chapter 3: Assembling a TBV123 Array on a TBV123-FB Flybar
- Chapter 4: Assembling a TBV118L Array on a TBV123-FB Flybar
- Chapter 5: Assembling a Mixed Array on a TBV123-FB Flybar
- Chapter 6: Assembling a TBV118L Ground Stack
- Chapter 7: Assembling a TBV118L Subwoofer and TBV123 Ground Stack
- Chapter 8: Assembling a TBV123 Array Ground Stack
- Chapter 9: Pole Mounting a TBV123 Cabinet on a TBV118L Subwoofer
- Chapter 10: Assembling an Inverted TBV123 Array
- Chapter 11: Using Eyebolts
- Chapter 12: Safety Inspection
- Chapter 13: TBV Enclosure Quantities and Combinations for TBV123-FB Flybar Suspension at 10:1, 7:1, 5:1 Design Factors
- Manufacturer’s Declaration
8 TBV123 / TBV123-AN and TBV118L / TBV118L-AN Rigging Manual
2.2 Rigging and Acoustic Simulation Software
The EASE FOCUS II software allows you to congure the system for optimal performance and coverage
in the venue.
The software can be downloaded from http://www.afmg.eu/index.php/products.html
Further information about the TBV models is available from www.turbosound.com
The TBV123 is a constant curvature line array, and the inter-cabinet angle is xed at 15 degrees.
The quantity of cabinets can be varied, and the SPL coverage calculated for any conguration.
Once an optimum system has been designed using the EASE FOCUS II software, the correct suspension hole on
the TBV123-FB ybar should be noted, where your bow shackle would be tted for single-point suspension.
For two-point suspension, pick point holes #1 and #6 can be utilized in conjunction with front and rear chain
motors to obtain the desired array site angle.
The EASE FOCUS II screenshot below is for a typical TBV123 conguration. Check the “RIGGING” Tab and note
installation parameters such as: array weight, bottom element elevation above ground level,
bottom enclosure angle.
WARNING
ERROR AND WARNING INDICATIONS ARE GIVEN IN THE OBJECT PROPERTIES WINDOW IF WORKING LOAD
LIMITS ARE EXCEEDED AT 10:1, 7:1 OR 5:1 DESIGN FACTORS. HEED THESE WARNINGS AT ALL TIMES IN
ACCORDANCE WITH LOCAL REGULATIONS.
EASE FOCUS II Typical Screenshot for a TBV123/TBV118 Mixed Array
Rigging Tab Shows the layout graphically,
and indicates the correct suspension pick
point to choose on the ybar.
15°
15°
15°
15°