User Manual

12 TFM-AN/TFX-AN Series Quick Start Guide 13
Fullrange Function
SETUP
(page 2)
Version Displays the installed  rmware version.
LOAD
1. - 20.
To load a speci c preset, turn the encoder to select the desired pesets number, and then either
the ENTER button or the encoder. When asked to con rm press the encoder again or EXIT to abort.
SAVE
1. - 20. To save a preset choose the respective preset slot and press ENTER or the encoder.
Sub Menu
Save Preset
Name the preset by choosing the characters with the encoder and pressing to con rm
each character. When  nished, press the ENTER button to save the preset.
SETUP
Contrast Adjust LCD panel contrast, The default contrast value is 15.
Screen
ON: LCD screen saver (default) turns on automatically after approx. 2 minutes.
OFF : LCD turns o automatically after approx. 5 minutes.
Logo
OFF: Deactivates front panel logo illumination.
ON: Activates front panel logo illumination.
LIMIT: Logo will light up when the limiter is active.
Sub Menu
Lock
Lock the device and create a password by choosing the password characters with the encoder
and pressing to con rm each character. When  nished press the ENTER button. Unlock the
device by entering the password or connecting the unit via USB to a PC running proprietary
remote software. The software does not require a password.
Warning
In case of overheating, an alert appears on the LCD screen, and the ampli er will shut down until
the unit cools.
LCD Graphic Indicators
To help the user immediately recognize that a parameter has been selected and changed from the initial default setting, the parameter’s related text on the top-level
screen will invert and change to black text on a white background. As an example, the following screenshots show how the text for the EQ function changes when the
TFM-AN/TFX-AN default EQ setting has been changed:
This indicator function occurs only on the main DSP menu level and works for all DSP-related functions, except for the LOAD, SAVE and SETUP sub-sections on the
second page of the top-level SETUP menu.
TFM-AN/TFX-AN DSP Menu Structure
Fullrange Function
PROCESS
EQ
None Sets the frequency response to the default setting.
Vocal Sets the frequency response to give an ideal monitor speaker for vocals.
Speech Sets the frequency response for optimal speech intelligibility.
Playback Sets the frequency response ideal for music playback.
User Lets you de ne your own frequency response setting by entering the corresponding sub-menu.
XOVER
None Unit is set for default full-range / subwoofer reproduction.
HP 120 Hz Preset with 120 Hz, 24 dB/octave  lter for crossover between subwoofer and full-range speakers.
HP 100 Hz Preset with 100 Hz, 24 dB/octave  lter for crossover between subwoofer and full-range speakers.
User User crossover sub menu for combination with other full-range or subwoofer speaker systems.
Sub Menu
Freq
Select the desired crossover frequency:
Fullrange systems: 75 Hz to 400 Hz.
Phase Adjust the absolute phase (0° or 180°).
FBQ
Auto
Automatically sets as many  lters as required. Whenever a new feedback frequency is discovered,
the  rst  lter will be released to attenuate the new frequency, and so forth.
Single Activates the FBQ (feedback detection) functionality, up to 8 feedback  lters.
Learn
Automatic procedure which searches for feedback frequencies and locks settings after all
8  lters have been set.
WARNING!
Please use ear protection during this procedure. The feedback signal may approach
the system’s maximum level, which may cause hearing damage!
Reset Resets all  lters.
SETUP
(page 1)
INPUT
Input
Lets you choose the audio input source. Choose between Local (analogue Input) or ULTRANET
(e.g., P16 monitoring system or M32 audio via ULTRANET).
Volume
Adjusts the input gain. With ULTRANET digital inputs over a range from +10 dB to -30 dB.
With analogue input from 0 dB to -∞ dB.
POSITION
Stand For positioning the speaker on a pole mount stand (full-range) or on the  oor (subwoofer).
Floor For positioning the speaker on the  oor as a monitor speaker (wedge).
Corner
For positioning the speaker in a corner next to the ceiling ( xed install); For positioning the
speaker in a corner (subwoofer).
DELAY
Delay Adjusts the amount of delay (max 300msec = 103.08m or 338.19 feet).
Unit Selector between msec, meter and feet.
LIMITER
Limit
Adjust the limiter threshold for the input signal (from OFF down to -30 dB). This threshold
adjustment allows you to set a max output power which is below the speaker systems
rated max output.