USER MANUAL PORTABLE AIR CONDITIONER Model: Green and Gl POACH Before using TURBO Portable Alr Conditioner, please read this manual carefully and retain It for future oie hah ge gee LOWBROW
English www turboprop Tips for First-Time Use 1. Allow the unit to sit upright for at least 3-4 hours before powering on. Shipping carriers may set the unit on its side, which causes the refrigerant to pool in certain areas. Standing the unit upright for 3-4 hours allows the refrigerant to move freely within the coils. 2. Some parts with sharp edges may cause injury, so gloves are highly recommended for unpacking and installing 3.
English www.turbro.com SAFETY INFORMATION Please read all instructions before use and save this user manual for future reference. A digital version can be obtained from Customer Support Your safety and the safety of others are very important to us. We have provided many important safety messages throughout this manual and on the appliance itself Always read and follow all posted safety messages.
English www.turbro.com ® The mains socket matches the plug. If this is not the case, have the plug replaced ® The mains socket is adequately earthed. Failure to follow these important safety instructions absolves the manufacturer of all liability. Important information for correct disposal of the product in accordance with EC Directive 2012/19/EV. At the end of its working life, the product must not be disposed of as urban waste.
English www.turbro.com IMPORTANT Grounding Method @® This product is equipped with a power supply cord that has a three-pronged grounded plug.
www turboprop Hose Inlet Exhaust Hose 1st Hose Outlet TF TF Window Panel + Adjustment Panel oo ¥¥ ¥% Metal Locking Screw 1 set Extension Panel without Hole PCs Remote Control 1 set Battery se! Drainage Hose apes Foam Seal (self-adhesive) 1st Installation =i] ® The air conditioner should be placed on a firm floor to minimize noise and vibration.
English www turboprop Tool Suggested Ea ii Phillips head screwdriver: Flat head screwdriver Saw \ Tape measure Scissors Pencil The window panel kit has been designed to fit most standard windows that open vertically or horizontally; however, it may be necessary for you to improvise/modify some aspect of the installation procedures for certain types of window. The included window panels don't fit for tilting or casement windows. You need to purchase a window seal pack (it's not included).
English www turboprop ¢. Place the assembled window panels on the window sash and adjust until it fully covers the width of your ' ® —> Window width 02] Max inch ODO _ _ Min inch Window th Max &inch / Min Inch NOTE: If the width of your window is smaller than 20.5 inches, please remove the adjusting panel from the window panel and then cut the window panel to make the width of the window panel the same width as your window. d. Use the provided metal locking screws to secure the window panel kit.
English www turboprop Installing Ex 14,1) COOL & DEHUMIDIFY MODE: Air exhaust hose should be connected to the portable air conditioner. FAN MODE: Air exhaust hose should be disconnected from the portable air conditioner A. Required Parts: ® Hose Inlet ® Exhaust Hose ® Hose Outlet B. Assembly: a. Align both the arrows of the Hose Inlet connector and the Exhaust Hose, then rotate the Hose Inlet clockwise or counter-clockwise to lock into place. (see Fig. 1) b.
English www.turbro.com OPERATING IN SUCTION Control Panel Lae 8 ® Cool Fan Timer High oy HEN 0 Q Timer Button @ Decrease Button ( Fan speed Button (© Mode Button ® Increase Button ® ON/OFF Button Operating from the Control Panel The Control Panel enables you to manage all the main functions of the appliance, but to fully exploit its potential, you must use the remote control TURNING THE APPLIANCE ON @ Plug into the mains socket, then the appliance is in standby.
English www.turbro.com COOL MODE Ideal for hot muggy weather when you need to cooling and dehumidify the room ® Press the Mode Button 8 until the ‘Cool’ indicator lights up. Also, the screen will appear i @ Press the A or W button to select your desired temperature 18°C -32°C (64°F -90°F) @® Press the Fan Button &% to select the fan speed. The indicator light shows the selected speed High To reach the desired temperature as rapidly as possible. Low To operate under low noise.
English www turboprop Programming shut down ® With the unit on, please press the Timer Button ® , the timer indicator and the screen digital will flash. Choose the required delayed shut-down time and wait for about 5 seconds. When the timer is active, the Timer" indicator will keep stay on and the screen will display = ~ ® Press the Timer Button ® again, the timer will be canceled, and the ‘Timer’ indicator will disappear.
English www.turbro.com Max Range: 23 feet/7 meters co Ep Inserting or replacing the batteries @® Remove the cover on the rear of the remote control ® Insert two "AAA" 15V batteries in the correct position (see instructions inside the battery compartment) NOTE: @ If the remote control unit is replaced or disposed of, the batteries must be removed and discarded in accordance with current legislation as they are harmful to the environment. @® Do not mix old and new batteries.
English www turboprop @® The actual temperature at its location will be displayed on the screen of the remote. The remote control will send this signal to the air conditioner every 20 minutes interval. If the air conditioner does not receive the Temp Sensing signal during any 25 minutes interval, the unit will exit the Follow Me Mode automatically. ® To cancel this function, press the =| button, and then press 4A or ¥ button until the Temp Sensing symbol & flashes on the display screen.
English www turboprop Method B: Continuous Draining a. Switch off the device and disconnect it from the mains by pulling out the mains plug b. Remove the drain cap from the lower or middies drain port. During this step, some residual water may spill so place a receptacle pan (does not include) under the drain port to collect the water. ¢. Insert the 1/2" drain hose into the drain port. The water can be continuously drained through the hose to the floor or a bucket.
English www.turbro.com @ Never use the appliance outdoors. @® Make sure the appliance is standing on a level surface. If necessary, place the castor locks under the front wheels THT close doors [] close do not cover and windows curtains the appliance Before cleaning or maintenance, turn the appliance off and wait for a few minutes, then unplug from the electrical outlet Cleaning the Outer Case You should clean the appliance with a slightly damp cloth then dry with a dry cloth.
English www turboprop Maintenance Checklist: Pr-Season Maintenance Checklist ® Check the power cord for any cuts or exposed wiring ® Check the ground prong is still on your power plug ® Clean the air filter ® Check whether the hose adapters and exhaust hose are installed tightly and free of damage Post-Season Maintenance Checklist ® Disconnect unit from the power outlet ® Clean air filter and exterior case ® Drain any accumulated water from the air conditioner @® Wrap the air conditioner in plastic to preve
www turboprop Troubleshoot your problem by using the chart below. If the air conditioner still does not work properly, please contact TURBO customer service team via We usually reply to you within 1 business day. Does not start o . Didn’t plug into the electrical a Plug inch the required wall outlet blowing from b. Air outlet / inlet is blocked when pressing outlet b. Wait for 30 minutes, if the problem can’t the ON/OFF b.
English wwwiturbro.
English wwwiturbro.com What is not covered? @® Damage caused by the owner when attempting to fix or alter the predict themselves. ® Damage caused by misuse, abuse, neglect, alterations, or unauthorized repair. @® Natural depreciation ® Any alteration misuse of the product will nullify this warranty. ® This warranty is non-transferable, which is effective for the original buyer from the authorized seller only.