14. To start timer again repeat step #1. It is best to get several readings on an area to
get the average infiltration rate.
15. If the infiltration rate is slow, a thirty minute or an hour long test may be desired, if
the infiltration rate is fast (In new sand construction), a five minute test may be
sufficient.
16. After using your Turf-Tec Infiltrometer, wash the cutter blades, dry, and spray with
silicone (this will help the Infiltrometer to remove a clean plug and prevent rust).
NOTE: Timer operates on a 1.5 volt “AAA” battery and is good for a long period. To
replace battery, remove timer by loosening two screws located on the backside of the face
plate and then removing timer. Replace battery located inside timer body under battery
cover. Be sure to replace battery cover when new battery is installed and then re-attach