INFILTRATION RINGS
MONITORING RECORD (SAMPLE PAGE)
We suggest recording your results along with these certain variables on this page:
PLACE: ______Drainage Project # 4________ DATE: _____7/31/12________
TIME: _____6:30 am_____ EXACT LOCATION: _Northwest corner of property _
FORMER RAINFALL / IRRIGATION INFORMATION
No rainfall, past 48 hours
1/4 inch irrigation, 28 hours ago.
PENETROMETER (COMPACTION) READINGS: ( 55 ) %
MOISTURE SENSOR READINGS AT DIFFERENT LEVELS
MOISTURE AT 1" INCH LEVEL : ( 35 ) %
MOISTURE AT 2" INCH LEVEL : ( 50 ) %
MOISTURE AT 3" INCH LEVEL : ( 60 ) %
MOISTURE AT 4" INCH LEVEL : ( 80 ) %
INNER RING INFILTRATION INNER RING INFILTRATION
RATE ACTUAL RATE CALCULATED
1 MINUTE : ( ) ML X 60 =
( ) ML PER HOUR
5 MINUTES : ( ) ML X 12 =
( ) ML PER HOUR
15 MINUTES : ( 100 ) ML X 4 =
( 400 ) ML PER HOUR
30 MINUTES : ( 150 ) ML X 2 =
( 300 ) ML PER HOUR
60 MINUTES : ( 300 ) ML X 1 =
( 300 ) ML PER HOUR
ANNULAR SPACE INFILTRATION ANNULAR SPACE INFILTRATION
RATE ACTUAL RATE CALCULATED
1 MINUTE : ( ) ML X 60 =
( ) ML PER HOUR
5 MINUTES : ( ) ML X 12 =
( ) ML PER HOUR
15 MINUTES : ( 175 ) ML X 4 =
( 700 ) ML PER HOUR
30 MINUTES : ( 300 ) ML X 2 =
( 600 ) ML PER HOUR
60 MINUTES : ( 600 ) ML X 1 =
( 600 ) ML PER HOUR