Product Manual
Page 5
Copyright Turf-Tec International - www.turf-tec.com
1471 Capital Circle NW #13, Tallahassee, FL. 32303 - USA
INFILTRATION RINGS
MONITORING RECORD
(SAMPLE PAGE)
We suggest recording your results along with these certain variables on this page:
PLACE: ______Drainage Project # 4________ DATE: _____7/31/07________
TIME: _____6:30 am_____ EXACT LOCATION: _Northwest corner of property _
FORMER RAINFALL / IRRIGATION INFORMATION
No rainfall, past 48 hours
1/4 inch irrigation, 28 hours ago.
PENETROMETER (COMPACTION) READINGS: ( 55 ) %
MOISTURE SENSOR READINGS AT DIFFERENT LEVELS
MOISTURE AT 1" INCH LEVEL : ( 35 ) %
MOISTURE AT 2" INCH LEVEL : ( 50 ) %
MOISTURE AT 3" INCH LEVEL : ( 60 ) %
MOISTURE AT 4" INCH LEVEL : ( 80 ) %
INFILTRATION RATE INFILTRATION RATE
ACTUAL CALCULATED
1 MINUTE : ( ) INCHES X 60 = ( ) INCHES PER HOUR
5 MINUTES : ( ) INCHES X 12 = ( ) INCHES PER HOUR
15 MINUTES : ( 1 ) INCHES X 4 = ( 4 ) INCHES PER HOUR
30 MINUTES : ( 2 ) INCHES X 2 = ( 4 ) INCHES PER HOUR
60 MINUTES : ( 4 ) INCHES X 1 = ( 4 ) INCHES PER HOUR
A free Excel spreadsheet that will auto calculate this page can be downloaded at
www.turf-tec.com