Before beginning a test, session be sure to have the necessary app settings selected via the App settings screen. Specific
settings are detailed in the App settings area of this manual; the specific settings for standard procedures are available in
the Testing procedure section.
1. Tap the NEW button under a Drop site to bring up the Run session screen.
2. Verify the onscreen details.
• Drop site location (at left)
• Serial number and status of Clegg device connection (at left)
• Drop locations, add additional locations by tapping “+” icon (at left)
• Enter desired Site conditions in available test area (at left)
• Drop Type: Make sure this reads PEAK (at right); controlled via App settings
3. Connect Clegg device by tapping CONNECT button, if necessary
• A connected device will become disconnected after 30 minutes of downtime.
• A disconnected device will power off after 10 minutes. For more information about how to power up the device, see
the Control: Power section on page 5.
4. Follow the appropriate Testing procedures. Standard testing procedures are available in the Performing a Clegg Impact
Test section on page 7.
SELECTING A DROP LOCATION
The listing of Drop locations can be traversed in multiple ways. In order to go down
the list in sequential order tap the NEXT LOCATION button above the Drop location
list. If you desire to move through the list in any order, tap a location name from the
list. The currently selected Drop location is highlighted in green.
For each test, it is helpful to acquire GPS coordinates for each test location. The display
also shows accuracy of GPS coordinates.
NOTE: Depending on the desired protocol, multiple drops may need to be associated
with a single Drop location. Each drop score is listed in order and can have comments
added describing any details pertaining to that specific drop. The individual scores and
comments will be available for viewing after the session has concluded. For more
information about viewing previous scores, see the Scoring section on page 15.
DELETING UNWATED READINGS:
1. If a drop is recorded improperly, you can delete that reading by clicking on the incorrect reading on the left.
2. Next click on “Delete”
3. Verify the Delete function