Dimensions Guide

POLY-CLASSIC
®
CRAFTSMAN SERIES SPECIFICATIONS
PRODUCT DESCRIPTION
Craftsman Series columns are manufactured using expanded cellular PVC and can be trimmed, fastened and drilled with ordinary
woodworking tools. Craftsman Series columns have a Limited Lifetime Warranty against rot, corrosion and moisture damage. Crafts-
man Series columns must be painted with two coats of acrylic latex paint applied according to the paint manufacturer's instructions.
Columns that are installed in direct sunlight will perform best when painted with light colors to minimize thermal gain that can cause
warping.
Craftsman Series Columns are manufactured using our E-Z Lock Miter Joint that aids in assembly, aligning the corners for a perfect fit
and keeping the column square. If installing in cold temperatures (less than 50 degrees) pre-drilling is required before using fasten-
ers. Cellular PVC becomes more brittle in cold temperatures and can be damaged if care is not taken during installation. If repair is
required any two part epoxy or two part body filler will work well. Coarse thread galvanized sheetrock or decking screws work best to
fasten cellular PVC. Pin nailing will also work well when using non-corrosive pin nails with larger heads. All screws or nail heads
should be countersunk. PVC cement or 100% waterproof polyurethane adhesives work well to assemble Craftsman columns.
Craftsman Series column shafts are 3/8" under nominal width and 1/2" under nominal length. Columns are shipped KD to aid in as-
sembly around a structural post and to allow for field trimming. To provide a custom fit, non-tapered plain columns can be trimmed
to any length. Non-tapered fluted, recessed panel and raised panel columns can be trimmed up to 6". Tapered plain columns can be
trimmed up to 12", and tapered recessed panel or raised panel columns can be trimmed up to 6". Tapered columns must be trimmed
from the bottom only and will change the
reveal on the base. The base can then be
trimmed to match the reveal of the cap or
left as is. The tapered column base detail is
shipped loose and is applied after the col-
umn is trimmed and installed, and the caps
for tapered columns come assembled. Caps
and bases for non-tapered columns are
shipped loose and simply wrap around the
column.
Craftsman Series columns are not load bear-
ing and require a load bearing structure in
place before installation. If a wood post is
used it must be pressure treated. Columns
should be trimmed 1/4" shorter than the
opening to allow for expansion.
PANEL STYLES AVAILABLE
ASTM DESIGNATION TEST TITLE Results
D256 IZOD Impact Resistance 0.246 ft. lb/in. Width
D570 Water Absorption (24 Hour exposure) 0.50%
D635 Rate of Burn Failed to Ignite
D638
Tensile Strength 1,889 psi
Modulus of Elasticity 107,000 psi
Elongation 10.20%
D648 Heat Deflection Temperature under Load 153 F
D696 Coefficient of Linear Thermal Expansion 0.0000327 in/in F
D790 Flexural Strength 4019 psi
D792 Specific Gravity / Density 0.55 g/cc
D1761
Fastener Withdrawal - 2" Staples 69
Fastener Withdrawal - 1" #10 Wood Screw 422
Fastener Withdrawal - 2" Galvanized Nails 108
D5420 Impact Resistance (Drop Dart) 98
E84 Surface Burn Characteristics 20

Summary of content (10 pages)