Ad gal] Contents Product Overview o-u 2 1. Specifications 2 2. Introduction ome 3 3. Warnings and Safety Notes 3 4. Recommended Connected Way 4 5. Standard Battery Parameters a Operation and Setup ooo 5 1. How to Confirm Charging Current ooo 5 2. Operative S Kills «o-u 5 3. Charger Settings names 6 4, Task Parameters oo 7 5. System Parameters Rena 8 6. Task Settings romeo eee 3 7.
REACTOR introduction Wireless Charging DC Port AC Port Channel Switch USB Port 5V Balance Port — Update Port for Channel 1 Battery Port Speed Shuttle Ke for Channel 1 P Y Battery Port for Channel 2 : Balance Port for Channel 2 Warnings and Safety Notes 1. Do not use the charger in an unattended manner, in case of any functional abnormality, please stop using it and refer to the manual. 2.
Recommended Connected Way 1. Connect the power supply, wait for self-checking to be completed; 2. Select the channel you wanna use then connect your battery to the chosen channel; 3. Set up charging parameters applicable to your battery through the display and speed shuttle key; 4. Enjoy. Standard Battery Parameters Ni | Nil haj 1.20v 3.20v 36v 3.70V 3.80v 1.50V av 3.70V 2.00v 120 ful ed 150v 365V | 410V 4.
REACH TOR How to Confirm Charging Current Operative Skills It is very important to know the maximum charging current of the battery as excessive current could influence the life span of battery and/or cause damages. In addition, excessive current can cause heating and/or explosion of the battery during the charging process. The charging and discharging capacity of battery is usually marked with C value.
Charger Settings Charger settings Seen aide ad Ena OL Sic = Fatah se Sn te Long press the shuttle key in standby interface to make the system default menu pop up, and the items are as follows: Adjust Safety Timer, Max Capacity, End Current and Trickle Charge Adjust Language, input power, input voltage and so on Used for channel 1 data calibration Used for channel 2 data calibration Start charging Self-checking Restore all parameters to factory settings(User calibration data cleanup} Display system informati
REACTOR Task Parameters CE ere oo nee oe he £ End Current tee Long press the shuttle key in standby interface to make the task parameters menu to pop up, and then choose task parameter item, the menu items are as follows: Ie Cut off exceed the setting time Cut off exceed the setting capacity Cut off less than the ratio between completed current and set up current ON or OFF Save all settings and exit, back to Charger Settings
System Parameters Long press the shuttle key in standby interface to make the System Settings menu to pop up, and < System Settings Fightback aw GE CL saa BL ve < Back then choose system parameter item, the menu items are as follows: 1)! u System language setting Input power limit setting Input voltage limit setting back light adjustment: high, middle, low ON or OFF buzzer volume adjustment: high, middle, low Single or Repeat VIC Customizing device names through shuttle keys Save all setting and exit the sy
REACTOR Task Settings Ea AS ad Bee Charge oat Sen ied # Connect the charger to the power supply and wait for the system to complete the self testing. Connect the battery to the charger under standby interface, and short press the shuttle key to make the task setting menu to pop up.
Task Settings The working mode of the D6 Pro AC/DC Balance Charger is series charging; you must therefore connect it to the output line of the battery while charging. For a lithium battery, it is highly suggested that the balanced interface should be connected to carry out balanced charging to accurately monitor the voltage of each cell and balance the ones with bad consistency.
REACTOR Task Settings Discharge Function Discharge function can discharge the battery. It is recommended to discharge the battery with balance port connection. Due to the limitation of internal discharge power, the discharge may be slow, which is a normal phenomenon. External Discharge Function External discharge function makes use of external high-power load resistance to discharge the battery accurately quickly.
Task Settings Internal Resistance Measurement Function D6 Pro AC/DC Balance Charger is equipped with a function of measuring the cells’ internal resistance, which is only applied when conducting balanced charging. The cell voltage should be measured and calculated within 2 to 3 minutes after the charging task has been initiated.
REACTOR Working Parameters Display Current Channel Device Name Completion Percentage Battery Type string Number Current Task Status Present Cap ac pasty Charged Current Current Operation Time Total Battery Voltage @ 4167v (0 a168v E) 4.160V 0 coll voltage @ 2160v @ s163v @ 2173v Fast Charging Scroll the shuttle key during operation can switch the display information in the lower half of the screen, which are cell voltage, cell internal resistance and run data.
Working Parameters Display Device Name Completion Percentage Current Channel Battery Type string Number Current Li Po 6504.
REACTOR Doers Working Parameters Display Current Channel Device Name Completion 1 S sd Percentage Battery . aan Nan a Type string : : : Number Current S80 Boils ie Task Status Present yi A —2 Lie Capacity Charged Current & ss a ie Operation Time Total Battery Voltage 4199v E)) 4.188Ve—— cell voltage O15 © 2198v @ s187v Discharging Scroll the shuttle key during operation can switch the display information in the lower half of the screen, which are cell voltage and run data.
Doers Working Parameters Display Current Channel Device Name Completion Percentage Battery Type string . Number Current 1 | (B Assisi e800 Boas Task Status Co vent Capacity Charged son Ti Total Battery operation Time Voltage Input Voltage — @— Charged Times 2 170wn Apes Operating Input Power Temperature External Discharge Long press the CH key to stop the current task.
REACTOR Working Parameters Display Current Channel Device Name Completion Percentage Battery 5 Type string er Nansen 0 Number Current — [| 80 Sac oldies ocr G00 i Task Status Present Capacity Charged Current Operation Time Total Battery @ 37s0v 743v E) 3.756V o—— cel Dotage Voltage @3s3v © 37s @ 374ev Storage Charging Scroll the shuttle key during operation can switch the display information in the lower half of the screen, which are cell voltage and run data.
Working Parameters Display Completion Device Name Percentage Current Channel Battery Type string Number Current Task Status Present . Current Capacity Charged Current Operation Time Total Battery Voltage €) 2105v © 4195v E) decolletage © 4190v @ 419v @ 4.183v Balancing Scroll the shuttle key during operation can switch the display information in the lower half of the screen, which are cell voltage and run data. Long press the CH key to stop the current task.
REACTOR Working Parameters Display Current Channel ~Operation Time Battery Type-string Number Current Task Status Present Current Capacity Charged Output © Battery Voltage ©) Current Channel Operation Time .. Battery Type-string umber Current Task Status Present Current Capacity Charged Output @ Voltage/power @ Battery Voltage Split-Screen Display Short press CH, display the channel you chose, long press the CH key to stop the current task.
® Error in power on self-checking the charger can automatically carry out a self-checking when connected to a power supply. A self-checking error warning sound should be heard when the charger is connected to the battery; power on after removing the battery for 5 minutes.
REACTOR # We warrant this product for a period of one year (12 months) from the date of purchase. The guarantee applies only to such material or operational defects, which are present at the time of purchasing the product. During that period, we will repair or replace without service charge any product deemed defective due to those causes. You will be required to present proof of purchase (invoice or receipt).