TU.
Contents 1. Specifications: 2. Features: 3. Charger’s exterior appearance 4. Warning and security tips 5. Program flow chart 6. How to set charge current 7. Lilo/LiPo/LiFe/LiHv battery program 8. NiMH/NiCd battery program 9. Pb battery program 10. Cell meter test program 11. IR test program 12. Memory program 13. User settings 14. Warning and error information 15.
1.Specifications: Input Voltage DC.10-18V Charge Current 0.1-6A Discharge Current 0.1-2A Charge Power max.50W Discharge Power max.5W Balance Current max.200mA Balance Tolerance ±0.01V LiXX:1-16cells Charging Capabililty NiXX:1-6series Pb Battery Voltage 2-20V Discharge Battery 3.0-4.
2. Features: Advanced Operate software The charger can set current automatically when charging/discharging. Especially for the Li-xx battery, it can avoid the explosion due to the wrong operation by user. All of them can set according to the user’s choice. The charger provide balance port for Li-xx battery, including 2, 3 ,4,5,6-cell five balance port. High power and high performance circuit The charger maximum output power is 50W, max. charging current is 6A, max. discharging current is 2A.
external temperature sensing line). Charge time Limit: It can prevent over charge and discharge by setting a charge time. Input current checking: In order to protect the battery it can check the voltage of the battery during charging process. The charger will turn off charge current with an alarm automatically when the voltage decreased to the lowest. Cooling Automatically: The cooling system will work automatically when the internal temperature is too high.
3.
4. Warning and security tips Never leave the charger unsupervised when charging, if any mal-function is observed please terminate the process immediately and refer to the manual. •Never put the charger into the place which dust/damp/vibrate. •The input power is only for DC 10-18V. •Please put it onto the surface which it is firm/Anti flammable. Never put it onto the carpet or others similar objects. Make sure it is far away from the Anti flammable area.
NiCd/NiMH Lilo LiPo Life LiHv Pb Voltage grade: 1.2v/cell llowed fast charge current: 1C~2C rely on the running of the battery. Discharger voltage cut off grade: 0.85v/cell (Nicd battery) 1.0v/cell (Nimh battery) Voltage grade: 3.6V/c Max charge voltage: 4.1V/cell Allowed fast charge current: 1C or less Min discharge voltage cut off grade: 2.5V/cell or More Voltage grade: 3.7V/cell Max charge voltage: 4.2V/cell Allowed fast charge current:1c or less Discharger voltage cut off grade: 3.
Discharge •The discharge parameter should be set according to the rest of battery capacity or decreased battery voltage. When discharging, it should be pay more attention to the discharge process. It must set the correct discharge voltage, in order to avoid the over discharging. Li-xx battery cannot lower than the lowest voltage, because it is easy to damage the battery. Normally, it do not need to discharge for the Li-xx battery. • Some batteries have memory function.
5 Program flow chart BATT/PROGRAM LiXX BATT - Start Enter Batt type Stop LiXX CHARGE STATUS STATUS LiXX BALANCE STATUS STATUS STATUS LiXX FAST CHG STATUS STATUS LiXX STORAGE STATUS LiXX DISCHARGE + STATUS BATT/PROGRAM NiXX BATT - Start Enter Batt type Stop STATUS NiXX CHARGE STATUS STATUS NiXX Auto STATUS STATUS NiXX DISCHARGE STATUS STATUS NiXX RE-REAK STATUS NiXX CYCLE + STATUS BATT/PROGRAM Pb BATT Pb CHARGE STATUS STATUS Load Factory Set Enter Pb DISCHARGE STATUS ST
The relationship between the C value and the charging time: charging time≥ 60min/charging c value(for example, it need 60-70 minutes to complete 1C charging ).Due to battery differences in energy efficiency conversion, this time may be extended. 7. Lithium battery(Lilo/LiPo/LiFe/LiHV)program Use these programs only when charging a lithium battery ( Lilo/LiPo/LiHV/LiFe) with a nominal voltage of 3.6V, 3.7V, 3.8V or 3.3V per cell, respectively.
This shows the number of cells you set up and the processor detects. ' R: ' shows the number of cells found by the charger and ' S:' is the number of cells selected by you at the previous screen. If both numbers are identical you can start charging by press Start/Enter button. If not, press Batt Type/Stop button to go back to previous screen. Then carefully check the number of cells of the battery pack to charge again. The screen shows the present situation during charge process.
7.3 'FAST' charging Lithium battery The charging current is getting smaller as the process goes to the near end term of Lithium battery chaging. To finish charging process earlier, this program eliminate certain term of CV process. Actually, the charging current will goes to 1/5 from the initial value to end the process while the normal chaging goes to 1/10 during CV term. The charging capacity may be a bit smaller than normal charging but the process time will be reduced.
7.5 Discharging Lithium battery The value of discharge current on the left side of screen may not exceed 1C for a maximum safety and the final voltage on the right should not be under the voltage level that is recommended by the battery manufacturer to avoid deep discharging. To start to discharge, press Start/ Enter key for more than 3 seconds. This shows the present state of discharge. To stop discharging press Batt type/Stop key once. 7.
8. NiMH/NiCd battery program These programs are for charging or discharging NiMH (Nickel-Metal-Hydride) or NiCd (Nickel-Cadmium) battery commonly used for R/C model aplications. To alter the value at the display, press Start/Enter key to make it blink then change the value using INC or DEC key.The value will be stored by pressing Start/Enter key once. To start the process, press Start/ Enter button for more than 3 seconds. 8.
8.3 Charge-to-discharge & discharge-to-charge cycle NiMH/NiCd battery Set the sequence on the left and the number of cycle on the right. You can use this function for balancing, refreshing and break-in the battery. To avoid rising temperture of the battery, there will a brief cool-off period that already fixed at 'User setting' after each charge and discharge process. The cycling number ranges from 1 to 5. To stop the process, press Batt type/Stop key once.
9. Pb( lead-sulphuric acid) battery program This is programmed for charging Pb( lead-sulphuric acid) battery with nominal voltage from 2 to 20V. Pb batteries are totally different from NiCd or NiMH batteries. They can only deliver relatievely lower current compare to their capacity, and similar restrictions definitely apply to charge. So the optimal charge current will be 1/10 of the capacity. Pb batteries must not be charged rapidly. Always follow the instruction is supplied by the manufacturer of battery.
10 Cell meter test BATT/PROGRAM BATT METER Start Enter 4.16 4.18 4.18 4.16 This charger also can be used as a cell meter. It can show the average voltage and the highest/lowest voltage of each cells. Batt type Stop 4.17 V 4.17 V - Choose the cell meter program interface, press Start to see the individual 1-6cell’s voltage. + STATUS Press Start to show the highest/lowest voltage of the single cell and the voltage of each cell. MAIN 25.01V H4.178V L4.
12 Memory Mode B6 Charger can save setting data of each programs, it can save 10 groups data for each kind of battery, including the cells of the battery, setting charge current and so on. Users do not need to set the data again when they use the batteries which have been memory. Easy and convenient to use. BATT/PROGRAM BATT MEMORY Start Enter Select memory mode, press start to continue setting. Batt type Stop [ BATT MEMORY 1 ] ENTER SET- > - Press status to select the numbers you need to store.
13 User settings Safety ON Start Enter Timer 240min Batt type Stop Capacity Cut-Off ON 10000mAh - + STATUS Te m p C u t - O f f ON 80℃ 176℉ - + STATUS Temperature Unit Fahrenheit - + STATUS Rest Time CHG>DCHG - 5min + STATUS In the open state, when the charger starts to work, the safety timer automatically starts the timer at the same time. If the system is wrong or the system can't check the battery capacity is full, this setting can prevent the battery from overcharging.
NiCd Sensitivity D.Peak Default + STATUS The automatic charging trigger voltage is an automatic charging current closing program. The principle is that when the battery voltage rises to the highest point and starts to back down, it closes the charging current automatically to complete the charge process. If the trigger voltage is set too high, easy to cause overcharging. If the trigger voltage setting too low, the system may terminate the charge process too early.
14 Warning and Error information It will show the Error information with an alarm when use the wrong operation. 1.{" REVERSE POLARITY "} Battery output Polarity connection wrong; 2.{" CONNECTION BREAK "} Interruption between battery and output end, or the charger wire was not been connected well when charging/discharging. 3.{" OUTPUT SHORT CIRCUIT "} Short-circuit of the output terminal. Please check the charger wire 4.
15 Warranty and service We warrant this product for a period of one year(12 months) from the date of purchase. The guarantee applies only to such material or operational defects, which are present at the time of purchasing the product. During that period, we will replace without service charge any product deemed defective due to those causes. You will be required to present proof of purchase (invoice or receipt).