User Manual

Touch Board 9
2
Select eInstruction Device Manager.
The Device Manager window opens.
3
Select the Touch Board device from the Device Manager window.
4
Select the Calibrate icon from the toolbar.
The Calibration window opens.
5
Touch each target as it appears on the board.
TIP
For optimal accuracy, use a Touch Board pen during the calibration process.
NOTE
In addition to the Device Manager calibration, Windows 7 and 8 requires a second calibration when using
the Touch Board independent of WorkSpace. Refer to Calibrating the Touch Board (Windows 7 and
Windows 8) on page 9 for instructions on performing the second calibration.
Calibrating the Touch Board (Windows 7 and Windows 8)
Prerequisites
You must have administrative privileges to perform the Touch Board 16 pt. calibration. After the initial 16 pt. calibration, a 4 pt.
calibration can be performed by a non-administrative user. If you do not have administrative privileges, contact your IT
department.
1
From your computer, right-click the Turning Technologies icon in the
notification area.
2
Select eInstruction Device Manager.
The Device Manager window opens.
3
Right/control-click the Touch Board device from the Device Manager window.
4
Click Touch Settings.
The Tablet PC Settings window opens.
5
From the Tablet PC Settings window, click Calibrate.
NOTE
If the board has been previously calibrated, click Reset to erase previously stored calibration
data.
6
Touch each target as it appears on the board.
7
After the calibration, you must save the calibration data by clicking Yes from your keyboard or mouse.
NOTE
This calibration only needs to be performed once. If the Touch Board and/or projector is moved, you must
perform both calibrations again.
turningtechnologies.com/user-guides