Operation Manual

104
• Carefully place the Battery Hatch (with O-ring) into position
on the rim of the Battery Compartment, then press it evenly
and completely down into place with your same thumb.
• Maintain the Battery Hatch securely in place and, using your
other hand, slide the Retaining Ring down off your thumb
and into position around the Battery Compartment.
• The tabs on the Retaining Ring fit down into the two slots
located at the 2 and 8 o'clock positions.
• Using your fingers, turn the Ring counter clockwise 5
degrees until the tabs engage (Fig. 106), then tighten it 5
more degrees by turning it counter clockwise using the
Battery Hatch Tool (Fig. 107).
• While tightening the Retaining Ring, exert continuous
inward pressure on it until it is secured in the proper
position. A small symbol located on the Ring should be
aligned with the Locked symbol located on the Housing
(Fig. 107a)
Inspection
• Activate the unit and watch carefully as it performs a full
diagnostic and battery check, and enters Surface Mode.
• Observe the LCD display to ensure it is consistently clear
and sharp in contrast throughout the screen.
Fig. 107 -TIGHTENING the
RETAINING RING
Fig. 106 -ENGAGING the
RETAINING RING TABS
a