Operation Manual
12
• FREE Dive NiBG Alarm (Caution zone, 4 segments) - 3 beeps 3 times.
• Entry into Deco during a FREE Dive (Permanent Violation) - 3 beeps 3 times.
• Free Dive Mode Countdown Timer reaches 0:00 - each 3 beeps 3 times.
During the following NORM Dive situations, the 10 second continuous tone will be fol-
lowed by a 5 second steady beep that will not turn off when acknowledged -
• Ascending above a required Decompression Stop Depth for more than 5 minutes
(referred to as a Delayed Violation).
• Decompression requires a Stop Depth of 70 FT/21 M or deeper.
• Being on the Surface for 5 minutes after a Conditional Violation (Permanent Violation).
BACKLIGHT
> To activate the Backlight, while on the surface and during dives >> depress the S
button for 2 seconds.
• The Backlight will illuminate the display for button depression time plus the Duration
time set 0, 5, or 10 seconds.
(*The Backlight will turn Off if the button is held depressed for more than 10 seconds.)
• Press the button again to activate as desired.
NOTE: Extensive use of the Backlight reduces estimated Battery life.
Also, the Backlight does not operate during a Low Battery Condition
or when the Element II is connected to a PC.