Operation Manual

29
M
A
S
M
A
S
Set FO2 50% Default, information includes (Fig. 17):
> Graphics FO2, dFLt, and 50
> Set Point graphic OFF (or ON), flashing.
• Pressing and releasing the S button momentarily (< 2 sec)
will toggle between OFF and ON.
• Pressing and releasing the A button momentarily (< 2 sec)
will save the setting and revert to the Set F screen.
• Depressing the M button for 2 seconds, or if no button is
pressed for a period of 2 minutes, operation will revert to
the NORM (or GAUG) Surface Main screen.
SET A GROUP
Set A >> Audible >> Depth >> EDT >> NiBG >> DTR >> PO2.
> Depressing the A and S buttons simultaneously for 4
seconds while the NORM (or GAUG) Surface Main screen
is displayed will access the Set A screen (Fig. 18).
> Pressing and releasing the A button momentarily (< 2 sec)
while SET A is displayed will access Set Audible Alarm.
SET AUDIBLE ALARM
This option allows the Audible Alarm to be disabled. Due to
their importance, some cautionary situations will cause the
Audible alarm to sound even if this feature is set to OFF.
Fig. 17 - SET FO2 DEFAULT
Fig. 18 - SET A (Alarms)