Installation Instructions
Table Of Contents
- 页 1
- 书签7A2CEC03 For Models : 6736197, 6736272, 6736273, 6736274
- 书签AA530C4D Forden
- 书签0FFC6222 Single Handle Shower Faucet With Slide Bar Showerhead
- 书签E7AD372B Adjustable Wrench Groove Joint Plier
- 书签CB377D7F Teflon Tape Included
- 书签3F5CBFEB Needed
- 书签EDB4F447 Power Drill
- 书签C4A3667E connections with Teflon tape. Always wrap in a clockwise direction.
- 书签16243472 TUSCANY
- 页 2
- 书签75E1BDF1 27
- 书签7BE091FC Valve Body
- 书签EF973C10 End Cap
- 书签EDBF1190 Cartridge Housing
- 书签F427B8C7 Lock Nut
- 书签1070B38E Protective Sleeve
- 书签C6784E0C Screws
- 书签CD24BA50 Sealing Washer
- 书签63EF05FE Stopper
- 书签387C3D7F Spring
- 书签62F443FD O-rings
- 书签AFB7715E Adjuster
- 书签AFA969AA O-ring
- 书签68086E82 Adjuster Seat
- 书签9082A85F Escutcheon Gasket
- 书签694EDE02 Sealing Ring
- 书签D577BA12 Escutcheon
- 书签75998EBE Handle
- 书签905225E6 Set Screw
- 书签AEC29415 Showerhead
- 书签0FFC3D4F Shower Hose
- 书签F5E6522B Shower Holder
- 书签E4792A64 Wall Supply
- 书签291ED645 Slide Bar
- 书签5A6FBDD5 Base Support
- 书签B7B2717A Trim Cap
- 书签D33370A1 Screws
- 书签7221BA11 Wall Anchors
- 书签8BF32C23 Handle Button
- 书签015E6B8E Allen Wrench
- 书签2C9FA80C O-rings
- 书签6E89DB1E Screws
- 书签E76BA9D2 Plaster Guard
- 书签B651BFEB Stop Valve
- 书签0AEB9092 Washer
- 书签074378F3 Cartridge
- 书签2EDC6C3B Washer
- 书签82FA8A59 Trim Cap
- 书签5206B931 22
- 书签329ABFCF 23
- 书签73AB7A52 24
- 书签114D0CF8 25
- 书签8B9D4A8D 26
- 书签1C0D73E5 27
- 书签86AD6553 28
- 书签305D009E 29
- 书签F9512B5A 30
- 书签860C83F1 31
- 书签23EDDD5F 32
- 书签A0803C26 33
- 书签71F090DF 34
- 书签F3153F6E 35
- 书签1B619161 36
- 书签A8A29ABF 37
- 书签150ABB1A 1
- 书签EA961DDA 2
- 书签1AC05C12 3
- 书签DD652A90 4
- 书签802EC2B2 5
- 书签0122E489 17
- 书签0DA3ADF7 18
- 书签88974EF1 19
- 书签83603DB5 20
- 书签57FB30D2 21
- 书签1946C17E 22
- 书签84D393A8 23
- 书签78C36F35 26
- 书签11195AF6 25
- 书签4CBDCAF6 21
- 书签D200A45A 31
- 书签319AF901 32
- 书签AB5C0261 33
- 书签2A2025C9 34
- 书签E33C1054 24
- 书签63401B66 27
- 书签DF08EC0D 28
- 书签9711E628 29
- 书签3D567D99 30
- 书签24C4B054 28
- 书签1A6A8B3C 9
- 书签D0EC0128 35
- 书签BA1903B4 6
- 书签17B8E789 7
- 书签DAB460DA 8
- 书签5F592B81 10
- 书签6EE9BF55 11
- 书签E0AFA897 12
- 书签B2B287BD 13
- 书签1CCC3C79 14
- 书签D2BE0088 15
- 书签4932AF9F 16
- 书签717A22CE 36
- 书签B13FB7E7 37
- 页 3
- 书签FD7BB702 1/2''-14NPT
- 书签F225CBFC Water Supply Stub Out
- 书签38AE6DCB 1. If this is not a thin wall mounting, the plaster guard \(#8\) may be removed from the valve body \(#3\). Note: Secure the valve body to the support cross board for stability.
- 书签C74965ED Step 1-5
- 书签EB0F9E68 8
- 书签C2ED6417 2. Apply Teflon tape to all pipe threads. Install an elbow at one end of the pipe. Install the other end to the wall supply \(#25\) diverter \(bottom hole\) of the valve body \(#3\). Secure the wall supply \(#25\) elbow to a 2x4 bracing.
- 书签7414F18C 3.Plug the shower diverter \(top hole\) of the valve body \(#3\), using the washer \(#2\) and end cap \(#1\). Note: For a watertight connection, wrap Teflon tape around all threads in a clockwise direction.
- 书签4FA0A79D 4. Install the nipple to the stub out, using the proper length nipple so that the nipple extends 3/8” from the finished wall. In order to assure proper function, piping from the bottom portion of the valve to the water supply stub out must be 1/2" nominal copper pipe or 1/2" iron pipe. Do not use PEX for the water supply stub out.
- 书签8071B9A1 5. Turn on the hot and cold water supplies and check for leaks. If a leak occurs, refer to steps 2 or 3. Turn on the faucet and let the water run for one minute. This will help clear any debris that may have come loose during installation and prevent the system from becoming clogged. Turn off the water supplies. Note: Turn on both the hot and cold water shut offs before turning the faucet on. Not turning on both will cause your cartridge to become pressure locked. If this occurs, see the troubleshooting guide.
- 书签522FB061 3
- 书签52D2939F 3
- 书签FFEEB918 3
- 书签6296CD3A 2
- 书签5815DD38 1
- 页 4
- 书签7A8986C4 Step 6-9
- 书签1F43F9BA Installation Instructions
- 书签8B40D71A 6. If still attached, remove the protective sleeve \(#35\) from the plaster guard \(#8\) by twisting the protective sleeve \(#35\) counterclockwise.
- 书签2D3234BE 35
- 书签89295033 8
- 书签515DB9A3 7. Temperature Limiting Device: Remove the trim cap \(#7\) and lock nut \(#6\). By default, the temperature limiting device is set to the highest temperature setting \(A\). In order to reduce the temperature, remove the temperature limiting device \(the red cap\) and turn the device clockwise to the desired temperature \(position B or C\). Reinstall the lock nut \(#6\) and trim cap \(#7\).
- 书签E90D7238 8. Verify the escutcheon gasket \(#17\) and sealing ring \(#18\) are attached to the escutcheon \(#19\). Slide the escutcheon \(#19\) onto the cartridge housing \(#5\) and secure with screws \(#34\) and O-rings \(#33\).
- 书签F3E68700 34
- 书签A30FB768 33
- 书签D4741804 19
- 书签648F145A 17
- 书签7CC1913D 18
- 书签16D8A02E 9. Slide the handle \(#20\) onto the cartridge \(#4\). Use the set screw \(#21\) to secure the handle \(#20\). Insert the handle button \(#31\). See the diagram for a visual.
- 书签C5DCEF7D 21
- 书签137942FD 31
- 书签5E6589CE 4
- 书签8CF1CBA7 20
- 书签F8EBF6FB 5
- 页 5
- 书签BD85299A Step 10-13
- 书签BE741D2E Installation Instructions
- 书签51B34D5A 10. Install wall supply \(#25\). See diagram for visual.
- 书签B2E2736E 25
- 书签3B24DF38 11. Determine placement of the slide bar. Drywall or Ceramic Tile Installation: Drill holes 5/16" and tap wall anchors \(#30\) into the wall. Slide the base support \(#28\) onto the slide bar \(#26\). Secure the assembly to the wall by screwing the screws \(#29\) into the wall anchors \(#30\), as shown in figure A. Insert the trim cap \(#27\) into the base support \(#28\). Wood Wall Installation: Drill holes 3/32". Slide the base support \(#28\) onto the slide bar \(#26\). Secure the assembly to the wall by screwing the screws \(#29\) into the wall, as shown in figure B. Insert the trim cap \(#27\) into the base support \(#28\).
- 书签F78AE734 A
- 书签7A8E03D9 B
- 书签FD23CC10 27
- 书签85559E3C 29
- 书签6160E65B 28
- 书签C9EDF93F 30
- 书签56EFEE06 26
- 书签CD2DD654 \(656mm\)
- 书签BF5523C4 30
- 书签091C5FA0 27
- 书签A1211B97 29
- 书签1B5E42AA 28
- 书签4E041AE3 26
- 书签48C2A42D 12. Turn on the water supplies and check for
- 书签28C3A7BB 13. Verify the washer \(#37\) is in the shower hose \(#23\). Install the shower hose \(#23\) to the wall supply \(#5\). Install the showerhead \(#22\) to the shower hose \(#23\).
- 书签47A018C6 23
- 书签0BA8C16E leaks. If a leak occurs from wall supply \(#25\) in the diagram, repeat step 10.
- 书签5E96B5CA 22
- 书签9D0EB648 25
- 书签6B03B009 30
- 书签7D9379CA 27
- 书签C6C59E83 29
- 书签E693041F 28
- 书签28A9A637 30
- 书签236725A7 27
- 书签891660F0 29
- 书签8306768E 28
- 书签E769DC99 37
- 页 6
- 书签229D14FC The lock nut \(#6\) has come loose or the O-ring on the cartridge \(#4\) is dirty or misaligned.
- 书签27BF5B47 Turn off the water supplies. Remove the handle \(#20\) and trim cap \(#7\). If the lock nut \(#6\) is loose tighten it. If the lock nut \(#6\) is tight, remove the lock nut \(#6\) and cartridge \(#4\). Verify the O-ring is clean and in proper alignment on the cartridge \(#4\). If the O-ring is dirty rinse it in warm water. Reinstall the O-ring onto the cartridge \(#4\). Reinstall the cartridge \(#4\), lock nut \(#6\), trim cap \(#7\), and handle \(#20\).
- 书签482150AC Rubber valve seat at the base of pressure balance cartridge \(#4\) is dirty or broken.
- 书签ED940EE7 Turn off the water supplies. Remove the handle \(#20\), trim cap \(#7\), lock nut \(#6\), and the cartridge \(#4\). Verify the rubber valve seat is damange free, clean, and in proper alignment on the cartridge \(#4\). If the rubber valve seat is damaged replace the cartridge \(#4\). If the rubber valve seat is dirty rinse in warm water. Reinstall the rubber valve seat onto the cartridge \(#4\). Reinstall the cartridge \(#4\), lock nut \(#6\), trim cap \(#7\), and handle \(#20\).
- 书签32D4C982 Turn off the water supplies. Remove the handle \(#20\), trim cap \(#7\), lock nut \(#6\), and the cartridge \(#4\). Inspect the cartridge for dirt and damage. Replace the cartridge \(#4\) if damaged. Shake the cartridge \(#4\) and verify the pressure balance spool \(located at the bottom of the cartridge \(#4\)\) is moving freely \(clicks when shaken\). If the spool is not moving, tap it on your hand until it begins to click. If the cartridge \(#4\) is dirty, soak it in warm white vinegar for 4 hours. Every 30 minutes, while the cartridge \(#4\) is submerged in the vinegar, rotate the stem on and off 10 times. Reinstall the cartridge \(#4\), lock nut \(#6\), trim cap \(#7\), and handle \(#20\). Turn the water supplies on.
- 书签CF069C82 The cartridge \(#4\) is dirty, damaged, or pressure locked.
- 书签2BF6EF18 The water temperature cannot be adjusted or there is no hot or cold water.
- 书签1F550BF5 Water will not shut off completely.
- 书签491D8F28 Leaks underneath the handle \(#20\).
- 书签6CC6D475 Revised on 05/19/2020
- 书签BCA3DCE7 The manufacturer warrants that the parts and assemblies of this product will be free from defects in material and workmanship under normal household use for as long as it is owned by the original consumer purchaser. This warranty covers the original purchaser with original receipt only and does not include business, commercial or industrial use of this product. This warranty shall not apply to goods which have been subject to accidents, negligence or improper installation. Our responsibility under this warranty is limited only to the replacement of parts and no other costs. Should a malfunction occur within the time covered by this warranty, replacement parts may be obtained from Customer Service Department 1-800-626-3525 or email warranty@cmiproduct.com. The manufacturer will, at its discretion, provide replacement parts for installation by consumer for any parts that prove defective under normal usage and care with new or equivalent parts.