Installation Instructions
Table Of Contents
- 页 1
- 书签7390C6B7 Flashlight
- 书签B691C0A8 Your new faucet is designed for years of trouble-free performance. Keep it looking new by cleaning it periodically with a soft damp cloth. Avoid abrasive cleaners, steel wool, and harsh cleaners at these will dull the finish and void the warranty. Vinegar is suggested as an alternative cleaner and is safe for all finishes.
- 书签E70D08D7 If soldering during the installation of this faucet, remove the seats, cartridges, and washers before adding any heat. The warranty will be voided on these parts if not removed before soldering.
- 书签BB244D0A Safety glasses should always be worn when cutting or soldering.
- 书签FE4B9625 Always cover your drain before installation to prevent losing parts.
- 书签7309C957 TUSCANY
- 书签D6A8A543 Before installation turn off the cold and hot water shut offs. Turn the faucet handle\(s\) on to release the pressure in the system. Before installing the water supply lines to the new faucet, turn on both water supply valves and bleed the water supply lines into a bucket for one minute to remove any debris that could clog the faucet. Wrap ALL threaded connections with Teflon tape in a clockwise direction. When installing the new faucet, turn the connectors finger tight, then use an adjustable wrench to tighten the connectors. Connections that are too tight will reduce the integrity of your system.
- 页 2
- 书签E41C5A19 Allen Wrench
- 书签CA52227F Screws
- 书签F52E2A3F 33
- 书签627CEDD9 End Cap
- 书签E6AED3B7 Aerator Assembly
- 书签F837E51A Side Spray Base
- 书签A3E48B27 Lock Nut
- 书签D343B95C Hose
- 书签560B82EE Gasket Assembly
- 书签70C596C1 Ring
- 书签0E34F4E6 34
- 书签85BF7E25 35
- 书签15A260DE 36
- 书签7756ACF2 37
- 书签2EFEFF9B 38
- 书签71B7B0F1 39
- 书签83B8AF80 O-ring
- 书签E3A99B46 Waterway Assembly
- 书签5C986CB1 Seal
- 书签EC58F3E3 Threaded Shank
- 书签501D453C 35
- 书签BB7A5518 36
- 书签8B8513EE 37
- 书签2E4AEEE3 38
- 书签A5D1C393 39
- 书签B56FE0EB 27
- 页 3
- 书签62591467 3. Side spray \(#26\) installation is optional. To install without the side spray \(#26\), unscrew the quick connect assembly \(#22\). Wrap the threads of the end cap \(#34\) with Teflon tape and tighten onto the waterway assembly \(#21\) the quick connect assembly \(#22\) was removed from. See diagram for an example. Note: Side spray \(#26\) installation is optional. Follow this step and skip step 6 to install faucet only. To install the side spray, skip this step and continue with step 4.
- 书签D32B7E13 4. Deck Plate \(3 Hole\) Installation: Attach the gasket \(#24\) and seal \(#25\) to the deck plate \(#23\), ensuring the notches on the deck plate \(#23\) line up for proper installation. Install assembly to the faucet. Apply silicone sealant beneath the gasket \(#24\). Install the faucet through the second hole from the left. Single Hole Installation: Apply silicone sealant beneath the body \(#7\). Install the faucet through the single faucet hole.
- 书签5E4D8764 1. Before installation turn off the cold and hot water shut offs. Turn the faucet handle\(s\) on to release the pressure in the system. Remove the current faucet. Thoroughly clean and dry the surface the new faucet will be installed on. Note: This faucet fits 1-1/2" countertops.
- 书签6E9C1C15 2. Remove the lock nut \(#31\) and gasket assembly \(#39\) from the threaded shank \(#28\). Note: Do not remove the customer service tag with the model number and phone number. This information will be needed when calling the customer service department.
- 书签4D76AEDC 39
- 书签6B2BCCAD 28
- 书签E401A67D 21
- 书签DBCB1F1C 22
- 书签F54617A7 34
- 书签449A018D 23
- 书签CAA2B5EC 24
- 书签37BEC4DB 25
- 书签3CE618F9 7
- 书签1936B445 7
- 书签DEE17704 Step 1-4
- 页 4
- 书签EB0C58EB 5. From underneath, reassemble the gasket assembly \(#39\), then screw on the lock nut \(#31\). Hand tighten the lock nut \(#31\) lining up one of the screws \(#32\) with the groove in the gasket assembly \(#39\). Do not over tighten. Use a Phillips screwdriver to tighten the screws \(#32\) on the lock nut \(#31\). Note: Assemble in the order listed with the rubber washer \(#29\) first. See the diagram for a visual. Hint: Have someone hold the body \(#7\) in place while tightening.
- 书签11507D92 Apply silicone sealant to the side spray base \(#36\), insert into the far right hole, and screw on the lock nut \(#37\). Slide the hose \(#38\) through the side spray base \(#36\) and connect to the quick connect assembly \(#22\). Note: The hose \(#38\) is fully connected when a light click or popping sound is heard.
- 书签E93F5620 water supplies in a clockwise direction. Tighten the water supply tubes/lines onto the water supply shut offs. Be sure to connect the cold water supply tube/line to the cold water supply valve \(typically on the right\) and the hot water supply tube/line to the hot water supply valve \(typically on the left\). Use a wrench \(as shown\) to tighten the nut. Hold the tubes/lines into a bucket and turn the water supply valves on for one mintue. Turn off the water supply valves.
- 书签27D8351C 39
- 书签E3B648F8 29
- 书签A874BDA6 30
- 书签7BB5B403 36
- 书签92AFFF7B 37
- 书签C1600274 38
- 书签8DFDC1FF 6. Side Spray Installation:
- 书签D2DF1ECE 7. Apply Teflon tape onto the threads of the faucet
- 书签075A8F78 Step 5-7
- 书签C193EBDB 7
- 页 5
- 书签BFFB6991 with Teflon tape. Slip 1/2" coupling nuts onto water supply tubes or use flexible stainless steel supply lines \(recommended\) - both are sold separately. Use two wrenches \(as shown\) to keep from twisting the supply tube off of the faucet when tightening the nut.
- 书签4A608242 9. Remove the aerator assembly \(#35\). Open the hot and cold shut offs and check for leaks. If a leak occurs, refer to step 7 or 8. Note: Remove by hand. Do NOT use pliers to remove the aerator assembly \(#35\) as this may cause damage.
- 书签43AE3C5E 10. Turn on both the hot and cold water and let it run for one minute. This will help clear any debris that may have come loose during installation and prevent the system from becoming clogged. Turn off the water and reinstall the aerator assembly \(#35\).
- 书签2D64CE94 35
- 书签06DB77FE 35
- 书签D171EE89 8. Wrap the threads of the waterway assembly \(#21\)
- 书签317F0B64 Step 8-10
- 页 6
- 书签6CC437C2 Revised on 10/22/2020
- 书签B01E399A Troubleshooting
- 书签AB469285 The lock nut \(#11\) has come loose or the O-ring on the cartridge \(#12\) is dirty or misaligned.
- 书签0AE30AA8 Release the pressure in the faucet system. Remove the handle button \(#3\), set screw \(#2\), handle \(#1\), and trim cap \(#4\). If the lock nut \(#11\) is loose tighten it. If the lock nut \(#11\) is tight, remove the lock nut \(#11\) and cartridge \(#12\). Verify the O-ring is clean and in proper alignment on the cartridge \(#12\). If the O-ring is dirty rinse in warm water. Reinstall the O-ring onto the cartridge \(#12\). Reinstall the cartridge \(#12\), lock nut \(#11\), trim cap \(#4\), handle \(#1\), set screw \(#2\) and handle button \(#3\). Turn the water supply valves on.
- 书签EC24BD24 Dirty or damaged cartridge \(#12\).
- 书签14FCE0A0 Release the pressure in the faucet system. Remove the handle button \(#3\), set screw \(#2\), handle \(#1\), trim cap \(#4\), lock nut \(#11\) and cartridge \(#12\). Check the ceramic disk for dirt and damage. If the cartridge \(#12\) is damaged, replace the cartridge \(#12\). If the cartridge \(#12\) is dirty, soak it in warm white vinegar for 4 hours. Every 30 minutes, while the cartridge \(#12\) is completely submerged, turn the stem on and off 10 times. Reinstall the cartridge \(#12\), lock nut \(#11\), trim cap \(#4\), handle, \(#1\) set screw \(#2\), and handle button \(#3\). Turn the water supply valves on.
- 书签0E06847D Leaks under the handle \(#1\).
- 书签27BF9B10 The water will not shut off completely.
- 书签BB1112EA Aerator assembly \(#35\) is dirty or misaligned.
- 书签57E05C2B The quick connect assembly \(#22\) is loose or misaligned.
- 书签CFEC6E1B Remove the aerator assembly \(#35\) and check the washer \(#8\). If the washer \(#8\) is misaligned, realign the washer \(#8\) and reinstall. If the aerator \(#9\) is dirty, rinse in warm water. Reinstall or replace the aerator assembly \(#35\).
- 书签4456468C Release the pressure in the faucet system. Release the hose \(#38\) from the quick connect assembly \(#22\). Unscrew the quick connect assembly \(#22\). Add Teflon tape to the threads and reinstall. Connect the hose \(#38\) and turn the water supply valves on. Test for leaks. If the quick connect assembly \(#22\) continues to leak, contact customer service.
- 书签103CB253 The aerator assembly \(#35\) leaks or has an inconsistent water flow pattern.
- 书签797AF8DC Leak at the quick connect assembly \(#22\).
- 书签CE405699 The manufacturer warrants that the parts and assemblies of this product will be free from defects in material and workmanship under normal household use for as long as it is owned by the original consumer purchaser. This warranty covers the original purchaser with original receipt only and does not include business, commercial or industrial use of this product. This warranty shall not apply to goods which have been subject to accidents, negligence or improper installation. Our responsibility under this warranty is limited only to the replacement of parts and no other costs. Should a malfunction occur within the time covered by this warranty, replacement parts may be obtained from Customer Service Department 1-800-626-3525 or email warranty@cmiproduct.com. The manufacturer will, at its discretion, provide replacement parts for installation by consumer for any parts that prove defective under normal usage and care with new or equivalent parts.
- 书签662D432B If the installation instructions have been followed carefully and the faucet still does not work properly, take these corrective steps. CAUTION: Faucets are under pressure. For safety, before preforming maintenance on the faucet always turn off the water at the water supply valve and turn on the handle\(s\) to release the pressure.